Page 1
SERVICE MANUAL UHF FM TRANSCEIVER iF2610...
Page 2
This service manual describes the latest service information NEVER connect the transceiver to an AC outlet or to a DC for the IC-F2610 UHF FM TRANSCEIVER at the time of pub- power supply that uses more than 16 V. This will ruin the transceiver.
SECTION 1 SPECIFICATIONS Measurement method ETS 300 086 Frequency coverage 400–430 MHz [L-band], 440–490 MHz [M-band], 490–520 MHz [H-band] × Number of channels 128 (16 ch 8 banks) 16K0F3E (25 kHz; [Wide]) Type of emission 8K50F3E (12.5 kHz; [Narrow]) Operating temperature range –20˚C to +55˚C Power supply voltage 13.2 V DC (negative ground)
Page 7
• RMK-1 connection ¡ Remove 3 allen-socket bolts from the front plate using an allen-wrench (1/32 in). ™ Separate the front unit from the transceiver main unit. £ Attach the ‘RMK-1 rear unit attachment’ to the transceiver main unit using the supplied screws. ¢...
SECTION 4 CIRCUIT DESCRIPTION 4-1 RECEIVER CIRCUITS The RF signals from the bandpass filter are mixed with the 1st LO signals, which come from the Rx VCO circuit via the 4-1-1 ANTENNA SWITCHING CIRCUIT LO amplifier (Q3), at the 1st mixer circuit (Q2) to produce a (MAIN UNIT) 30.875 MHz 1st IF signal.
The N/W switches (D501, D502) select a ceramic filter (FI3 • CTCSS AND DTCS or bypass), and the other N/W switch (Q61) adjusts the input The tone squelch circuit detects AF signals and opens the level of the FM IF IC (IC1, pin 8) to switch the bandwidth squelch only when receiving a signal containing a matching depending on the NWC signal from the CPU (IC20, pin 57).
Page 10
The N/W switches (IC502, Q65) are connected to the input The amplified signal is passed through the antenna switch- lines of the splatter filter section (IC22) and buffer amplifier ing circuit (D4), low-pass filter and APC detector. Then the (IC503) respectively. The N/W switches (IC502, Q65) are signal is applied to the antenna connector.
4-4 POWER SUPPLY CIRCUIT 4-3 PLL CIRCUITS VOLTAGE LINE 4-3-1 PLL CIRCUIT (MAIN UNIT) A PLL circuit provides stable oscillation of the transmit fre- LINE DESCRIPTION quency and receive 1st LO frequency. The PLL circuit con- The voltage from the external power connector. sists of the PLL IC, charge pump, loop filter and reference oscillator and employs a pulse swallow counter.
4-5 UT-103 CIRCUIT DESCRIPTION In case of the FFSK signal is used for the PM modulation, the FM/PM switch (IC2) is switcheded to pin 7. 4-5-1 GENERAL IC1 is the FFSK modem IC which is controlled by serial data In case of the FFSK signal is used for the FM modulation, bus line (“CCS”, “SI”, “SO”, “SCK”, “CIRQ”...
4-6 PORT ALLOCATIONS CPU (MAIN UNIT; IC20) Port Port Description Description number name number name Outputs the PTT control signal. Outputs strobe signals for the level PTTO DSTB Low : While transmitting controller. (IC5) Input port for the PTT control signal Outputs data signal for the level con- PTTI from PTTO port.
SECTION 5 ADJUSTMENT PROCEDURES 5-1 PREPARATION I REQUIRED TEST EQUIPMENT EQUIPMENT GRADE AND RANGE EQUIPMENT GRADE AND RANGE Output Voltage : 13.2 V DC Frequency range : 0.1–600 MHz DC power supply Standard signal Current capacity : 15 A or more Output level : 0.1 µV–32 mV generator (SSG)
Indicate the received signal level S-METER PC programming. In such case, cannot be used regardless of keys. and only ‘DISPLAY’ setting is available. Ask your Dealer or Icom Service Center for PC programming. Low 1 Low 2 High TX POWER I SELECTION METHOD MODE...
5-3 PLL ADJUSTMENT MEASUREMENT ADJUSTMENT ADJUSTMENT ADJUSTMENT CONDITIONS VALUE UNIT LOCATION UNIT ADJUST PLL LOCK • Operating freq. : 390.000 MHz MAIN Connect a digital multi- 2.0 V MAIN VOLTAGE 440.000 MHz meter or an oscillo- 480.000 MHz scope to the check •...
5-4 RECEIVER ADJUSTMENT ADJUSTMENT MEASUREMENT ADJUSTMENT ADJUSTMENT CONDITIONS METHOD VALUE ADJUST RECEIVER • Operating freq. : 400.000 MHz Number digits in the LCD Maximum indi- Adjust in sequence SENSITIVITY 440.000 MHz cation L8, L9, L11, L12, 490.000 MHz L13 on the MAIN •...
5-5 TRANSMITTER ADJUSTMENT ADJUSTMENT MEASUREMENT ADJUSTMENT ADJUSTMENT CONDITIONS METHOD VALUE ADJUST OUTPUT • Operating freq. : 400.000 MHz Connect an RF power meter to 24 W [25 W] Rotate volume POWER 440.000 MHz [M] the antenna connector. 10 W [10 W] control while 490.000 MHz [H]...
Page 28
[MAIN UNIT] [TONE UNIT] (UT-96 pre-installed version ONLY) ORDER ORDER DESCRIPTION DESCRIPTION B only C608 4030009530 S.CERAMIC C1608 CH 1H 030B-T 0880000150 UNIT BOARD EX-1643 #02 B only C609 4030009530 S.CERAMIC C1608 CH 1H 030B-T B only C610 4030007050 S.CERAMIC C1608 CH 1H 220J-T B only C611...
9-2 MAIN UNIT ([EUR-01/-02/-12/-13/-71/-72] ONLY) CHASSIS J1 • TOP VIEW BLACK MP12 IC11 MP15[L-R] MP15[M-R] MP9,MP8 J501 MP1, MP14 to optional cables OPC-821, OPC-822 DISC MP2,MP4 PAAF HORN to optional cable OPC-617 to optional units to optional unit UT-96,UT-103, EX-1761 EEPROM UT-105,UT-109, UT-110 to FRONT unit J2...
9-3 MAIN UNIT ([OTHER]) CHASSIS J1 • TOP VIEW BLACK MP12 IC11 MP9,MP8 J501 to optional cables OPC-821, OPC-822 DISC MP2,MP4 PAAF HORN to optional cable OPC-617 to optional units to optional unit UT-96,UT-103, EX-1761 EEPROM UT-105,UT-109, UT-110 to FRONT unit J2 9 - 5...
SECTION 11 VOLTAGE DIAGRAMS 11-1 FRONT UNIT LIGHT ON (DIM OFF) 7.64V LIGHT ON (DIM OFF) 7.75V LIGHT ON (DIM ON) 5.99V LIGHT ON (DIM ON) 6.20V LIGHT ON LIGHT OFF LIGHT OFF 7.98V LIGHT OFF 7.98V 5.04V 100k 100k 100k 100K 100k...
SECTION 12 OPTIONAL UNIT UT-103 • SCHEMATIC DIAGRAM • BLOCK DIAGRAM FM "OPEN" 100k PM "SHORT" C-BUS 1.8µ SIG OUT DISC IN to IC-F2610 TC4W53F SIG OUT 0.001 SIG OUT FX809LG MAIN unit J6 DISC IN FFSK AMP O 2,3,4...
Page 46
S-14005HZ-C1U 1-1-32, Kamiminami, Hirano-ku, Osaka 547-0003, Japan C 1999-2003 Icom Inc.
Need help?
Do you have a question about the IC-F2610 and is the answer not in the manual?
Questions and answers