Page 1
SERVICE MANUAL UHF FM TRANSCEIVER iF2610...
Page 2
IC-F2610 MAIN UNIT 05 pieces ceiver is defective. 8810008660 Screw BT M3x8 NI-ZU IC-F2610 Bottom cover 10 pieces 6. DO NOT transmit power into a signal generator or a Addresses are provided on the inside back cover for your sweep generator.
Page 4
SECTION 1 SPECIFICATIONS Mesurement method ETS 300 086 Frequency coverage 440–490 MHz × Number of channels 128 (16 ch 8 banks) 16K0F3E (25 kHz; Wide) Type of emission 8K50F3E (12.5 kHz; Narrow) Operating temperature range –20˚C to +55˚C Power supply voltage 13.2 V DC (negative ground) TX max.
Page 5
SECTION 2 INSIDE VIEW Low-pass filter circuit MAIN unit Power module* (IC11: SC-1323) RF amplifier* AF power amplifier (Q1: 3SK116) (IC8: LA4425A) 1st IF filter PLL IC* (FI1: FL-264) (IC12: MC145190F) Discriminator (X2: CDBC455CX16) (IC20: HD64F3437F16) FM IF IC* (IC1: MC3372SVM) EEPROM (IC27: X25650S8I-2.5) Microphone amplifier...
Page 6
SECTION 3 DISASSEMBLY AND OPTION INSTRUCTIONS • Opening cover • Installation location Remove 4 screws from bottom cover. Install option units. OPC-617 ACC CABLE: J4 UT-96 5-TONE UNIT UT-103 FFSK Logic Board or UT-105 SmarTrunk II Logic Board EX-1761 MEMORY EXPANSION UNIT: J7 OPC-821 AVL CONNECT CABLE J501 or OPC-822 INTERFACE CABLE...
Page 7
• RMK-1 connection ¡ Remove 3 allen-socket bolts from the front plate using an allen-wrench (1/32 in). ™ Separate the front unit from the transceiver main unit. £ Attach the ‘RMK-1 rear unit attachment’ to the trans- ceiver main unit using the supplied screws. ¢...
SECTION 4 CIRCUIT DESCRIPTION 4-1 RECEIVER CIRCUITS through the matching circuit (L14, L15) and a pair of crystal filters (FI1a/b) in order to obtain selection capability and to 4-1-1 ANTENNA SWITCHING CIRCUIT pass only the desired signals. The filtered signal is applied The antenna switching circuit functions as a low-pass filter to the 2nd IF circuit after being amplified at the 1st IF ampli- while receiving and a resonator circuit while transmitting.
4-1-5 AF AMPLIFIER CIRCUIT A portion of the AF signals from the AF amplifier (IC2) pass through the low-pass filter (Q503) and are then applied to The AF amplifier circuit amplifies the demodulated AF sig- the CTCSS decoder inside the CPU (IC20, pin 43) via the nals to drive a speaker.
4-2-2 MODULATION CIRCUIT 4-2-4 APC CIRCUIT The modulation circuit modulates the VCO oscillating signal The APC circuit protects the power module (IC11) from a (RF signal) using the microphone AF signals. mismatched output load and stabilizes the output power. The AF signals from the level controller (IC5) change the The APC detector circuit detects forward signals and reflec- reactance of varactor diode (D46) to modulate the oscillated tion signals at D3 and D1 respectively.
4-4 POWER SUPPLY CIRCUIT The lock voltage is also used for the receiver tunable band- pass filters to match the filter’s center frequency to the VOLTAGE LINE desired receive frequency. The lock voltage is amplified at LINE DESCRIPTION the buffer amplifier (Q29) and is then applied to the band- pass filters (D7–D11, D514).
4-5 PORT ALLOCATIONS CPU (IC20) Port Port Description Description number name number name Outputs the PTT control signal. Outputs strobe signals for the level PTTO DSTB Low : While transmitting controller. (IC5) Input port for the PTT control signal Outputs data signal for the level con- PTTI from PTTO port.
SECTION 5 ADJUSTMENT PROCEDURES 5-1 PREPARATION REQUIRED TEST EQUIPMENT EQUIPMENT GRADE AND RANGE EQUIPMENT GRADE AND RANGE Output Voltage : 13.2 V DC Frequency range : 0.1–600 MHz DC power supply Standard signal Current capacity : 15 A or more Output level : 0.1 µV–32 mV generator (SSG)
Indicate the received signal level S-METER PC programming. In such case, cannot be used regardless of keys. and only ‘DISPLAY’ setting is available. Ask your Dealer or Icom Service Center for PC programming. Low 1 Low 2 High TX POWER SELECTION METHOD MODE...
5-3 PLL ADJUSTMENT MEASUREMENT ADJUSTMENT ADJUSTMENT ADJUSTMENT CONDITIONS VALUE UNIT LOCATION UNIT ADJUST PLL LOCK • Operating frequency : 440.000 MHz MAIN Connect a digital multi- 2.0 V MAIN VOLTAGE • Receiving meter or an oscillo- scope to the check point “LV”.
5-4 RECEIVER ADJUSTMENT ADJUSTMENT MEASUREMENT ADJUSTMENT ADJUSTMENT CONDITIONS METHOD VALUE ADJUST RECEIVER • Operating frequency : 440.000 MHz Number digits in the LCD Maximum indi- Adjust in sequence SENSITIVITY • Enter Initial Set Mode No. 5. cation L8, L9, L11, L12, Refer to page 5-2 for details.
5-5 TRANSMITTER ADJUSTMENT ADJUSTMENT MEASUREMENT ADJUSTMENT ADJUSTMENT CONDITIONS METHOD VALUE ADJUST OUTPUT • Operating frequency : 440.000 MHz Connect an RF power meter to 25 W Rotate volume POWER • Enter Initial Set Mode No. 6. the antenna connector. control while Refer to page 5-2 for details.
9-2 MAIN UNIT ¡ ¡ TOP VIEW CHASSIS J1 BLACK MP12 C587 C586 IC11 MP9,MP8 J501 to optional cable OPC-821, OPC-822 MP2,MP4 DISC PAAF HORN R618 to optional cable OPC-617 to FRONT unit J2 to optional unit to optional unit UT-96, UT-105 EX-1761 EEPROM 0 - 5...
Page 34
SECTION 11 VOLTAGE DIAGRAM 11-1 FRONT UNIT LIGHT ON (DIM OFF) 7.64V LIGHT ON (DIM OFF) 7.75V LIGHT ON (DIM ON) 5.99V LIGHT ON (DIM ON) 6.20V LIGHT ON LIGHT OFF LIGHT OFF 7.98V LIGHT OFF 7.98V 5.04V 100k 100k 100k 100k 100K...
Page 35
11-2 MAIN UNIT [EXT SP] PAMIC 1/2VDD PAAF DATA BUS R162 C354 C344 0.001 0.001 PSET PSET +18V C184 +18V 0.001 C563 5.03 V R298 R348 C362 R148 R319 R304 0.56 R374 PLLIN 7.90 V 3.9k 0.001 R239 C279 C307 100k R303 C155...
Page 36
OPT AF BUS AF BUS 4.76 V SQL OPEN 4.81 V SQL CLOSE 0.12 V R62 1.5k 0.047 0.047 0.047 SQL OPEN 0.87 V 2.2k SQL OPEN 0 ,V R338 SQL CLOSE 4.56 V 3.96 V SQL CLOSE 4.21 V R595 2.51 V 2.53 V...
Page 37
11-2 MAIN UNIT [EXT SP] OPT AF BUS AF BUS 4.76 V PAMIC 1/2VDD SQL OPEN 4.81 V PAAF DATA BUS SQL CLOSE 0.12 V 0.047 SQL OPEN 0.87 V R62 1.5k 0.047 2.2k 0.047 R338 SQL OPEN 0 ,V R162 SQL CLOSE 4.56 V 3.96 V...
Page 38
08190 Sant Cugat del Valles Barcelona, SPAIN Phone : ( 93 ) 590 26 70 Fax : ( 93 ) 589 04 46 A Division of Icom America Inc. 3071 #5 Road, Unit 9, Richmond, B.C., V6X 2T4, Canada : http://www.icomspain.com...
Page 39
A-5547HI-SU 6-9-16, Kamihigashi, Hirano-ku Osaka 547-0002, Japan C C 1999 Icom Inc.
Need help?
Do you have a question about the IC-F2610 and is the answer not in the manual?
Questions and answers