ELECTRONIC PROBLEMS
Within this category are problems associated with the relays, microswitches, capacitors, resistors,
interface board, wiring, and controls. The most common problem in this category is a lift that
continuously travels up and down. This is usually caused by a microswitch that is out of adjustment.
Troubleshooting the electronics of a modular basket lift is simply a process of verifying current flow
through the individual components up to and including the motor. Using a multimeter set to the 250
VAC range, check the connections on both sides of the component for the presence of the applied
line voltage. The schematic below and the wiring diagram on page 1-15 identify the components
and wiring connection points.