SELF-DIAGNOSIS

The appliance has a self diagnosis system to identify a number
of malfunctions.
Error messages are displayed on the appliance display.
IF THE FOLLOWING APPEARS ON
THE DISPLAY...
"Low Temperature"
... DO THE FOLLOWING
The appliance has a defrosting device
that prevents excessive ice build ups. The
appliance automatically starts operating
again once the defrosting process is com-
plete.

TIPS FOR CORRECT USE

To ensure optimal results from your air conditioner, follow these
recommendations:
close the windows and doors in the room to be air condi-
tioned When installing the air conditioner semi-perma-
nently, you should leave a door slightly open (as little as
0.39 inch. (1 cm)) to guarantee proper ventilation.
Close doors and windows
Never use the appliance in very damp rooms (laundries for
example).
Protect the room from direct exposure to the sun by par-
tially closing curtains and/or blinds to make the appliance
much more economical to run
IF THE FOLLOWING APPEARS ON
THE DISPLAY...
"High Level"
... DO THE FOLLOWING
Empty the inner water tray by following
the instructions in the paragraph " END OF
SEASON OPERATIONS".
If the error occurs again, please contact
our toll free customer service call center.
11
IF THE FOLLOWING APPEARS ON
... DO THE FOLLOWING
If this appears, please contact our toll
free customer service call center.
Close blinds or curtains
Never use the appliance outdoors.
Make sure there are no heat sources in the room;
make sure the air conditioner is standing on a level surface.
do not cover the appliance
Never rest objects of any kind on the air conditioner;
Never obstruct the air intake or outlet grilles;
THE DISPLAY...
"Probe Failure"