  • Page 1 USER MANUAL Aqua TL...
  • Page 2: Contact Information

    Future Mobility Healthcare Inc. Customer Service Canada 6750 Professional Court Mississauga ON L4V 1X6 Phone: (888) 737-4011 or (905) 671-1661 Fax: (905) 671-3377 e-mail: orderdesk@futuremobility.ca www.futuremobility.ca COM AQUA TL UM REV. 02 AQUA TL...
  • Page 3: Table Of Contents

    IPPERS IGURE ANTI-TIP WHEELS ............... 11 MAINTENANCE ............... 30 ARMRESTS ................11 GENERAL MAINTENANCE ........... 30 BACK CANES ............... 11 SERVICE AND REPAIR ............30 FASTENERS................. 11 CLEANING YOUR CHAIR ............30 COM AQUA TL UM REV. 02 AQUA TL...
  • Page 4 16 WARRANTY ..............32 LIFETIME ................32 FOR TWO (2) YEARS ............. 32 FOR (90) DAYS ..............32 LIMITATIONS ............... 33 WARRANTY PROCEDURES ..........33 COM AQUA TL UM REV. 02 AQUA TL...
  • Page 5: Notice - Read Before Use

    REVIEW THIS MANUAL OFTEN Before using this chair you, and each person who may assist you, should read this entire manual and make sure to follow all instructions. Review the warnings often. COM AQUA TL UM REV. 02 AQUA TL...
  • Page 6: General

    Repair any problem. Your authorized supplier can help you find and correct the problem. COM AQUA TL UM REV. 02 AQUA TL...
  • Page 7: Changes And Adjustments

    Doing a “wheelie” means: balancing on the rear wheels of your chair, CENTER OF GRAVITY while the front casters are in the air. It is dangerous to do a "wheelie" as a fall or tip-over may occur. WARNING COM AQUA TL UM REV. 02 AQUA TL...
  • Page 8: Rolling Backwards

    DO NOT reach or lean over the top of the seat back. This may depression). damage one or both backrest tubes and cause you to fall. If You Must Reach Or Lean: COM AQUA TL UM REV. 02 AQUA TL...
  • Page 9: Transfers

    Never push or propel the chair with the seat tilted in a Stay at the rear of the chair. forward position. Several feet before your reach the edge of the curb or step, turn the chair around and pull it backward. COM AQUA TL UM REV. 02 AQUA TL...
  • Page 10: Climbing A Curb

    Face the curb and tilt the chair up on the rear wheels so that The attendants move to the next stair down. Repeat for each stair, until the front casters clear the curb or step. you reach the landing. COM AQUA TL UM REV. 02 AQUA TL...
  • Page 11: Component Warnings

    Over- or under-tightened fasteners may fail or cause damage to chair parts. COM AQUA TL UM REV. 02 AQUA TL...
  • Page 12: Footrests

    Make sure the rider cannot slide down in the wheelchair seat. rider or others. If this occurs, the rider may suffer chest compression or suffocate due to pressure from the belts. COM AQUA TL UM REV. 02 AQUA TL...
  • Page 13: Rear Wheel Axles

    Make sure wheel locks are embedded in tires at least 1/8 expect it. inch when locked. Make sure wheel locks are embed in tires at least 1/8 inch when locked. If you fail to do so, the locks may not work. COM AQUA TL UM REV. 02 AQUA TL...
  • Page 14: Features

    Frame Material: Stainless Steel or Electro polish • Frame Finish: Electro Polished or white Powder • Coat U-shaped detachable front rigging • • Flip up foot plates, choice of aluminum and composite-standard COM AQUA TL UM REV. 02 AQUA TL...
  • Page 15: Safety Inspection Checklist

    Adjust bearing system if wheel wobbles or binds to a stop. Ensure wheel bearings are clean and free of moisture. Check stem caster journal and lock nut for tightness Inspect casters for cracks and wear COM AQUA TL UM REV. 02 AQUA TL...
  • Page 16: Troubleshooting

    Please Note: Visual inspection of all parts for any deformation,corrosion,breakage.Check all fasteners on a regular basic to ensure that all connections remain secure Troubleshooting Solutions Check for loose nuts and bolts Check angle adjustable caster assembly COM AQUA TL UM REV. 02 AQUA TL...
  • Page 17: Labels

    Labels AQUA TL COMMODE (14”-20”) & (22”) WEIGHT CAPACITY 250LBS. (114KGS) REFER TO OWNER’S MANUAL WEIGHT CAPACITY 350LBS. (158KGS) REFER TO OWNER’S MANUAL COM AQUA TL UM REV. 02 AQUA TL...
  • Page 18: Front Riggings

    Ensure the Front Rigging is not loose and is ‘snug’ in place Repeat this procedure with the other front rigging assembly. COM AQUA TL UM REV. 02 AQUA TL...
  • Page 19 Slide the footrest stem up or down to desired height. There should be approximately 2-3/8” of range for the footrest extension. Re-tighten socket head button screw. Repeat this procedure with the other footplate assembly. COM AQUA TL UM REV. 02 AQUA TL...
  • Page 20: Installing And Adjusting The Front Arms

    ‘normal’ position grasp the top portion of the arm assembly and rotate the arm downwards to the position shown in the lower left corner until the FIGURE 2 arm comes to a stop. COM AQUA TL UM REV. 02 AQUA TL...
  • Page 21: Back

    Ensure the four (4) protrusions come thru the holes on the metal back frame and are not damaged. Fasten the new foam skinned backrest with two (2) 1/4-20 x 1/2” screws. COM AQUA TL UM REV. 02 AQUA TL...
  • Page 22: Seating

    The seat locking clip should ‘lock’ onto the frame tubing. The commode seat pad assembly should be ‘snug’ in place and should not be loose. COM AQUA TL UM REV. 02 AQUA TL...
  • Page 23: Potty

    The potty lid handle should be oriented vertical up to ensure that the potty assembly does not fall when it is picked up. Dispose the contents of the potty in the COM AQUA TL UM REV. 02 AQUA TL...
  • Page 24 The potty should ‘lock’ in place onto the wire potty holder. Ensure the potty is properly set in place with no means of falling from the commode if it is pushed or tilted. COM AQUA TL UM REV. 02 AQUA TL...
  • Page 25: Casters

    Remove the two snap clips located on the lower frame front side. Adjust the position of the caster assembly to the desired height and hold the caster assembly in place. Place the snap clip back into the lower frame COM AQUA TL UM REV. 02 AQUA TL...
  • Page 26 Note: When the height of the commode is changed one must ensure that the commode is stable and that one wheel is not higher or lower than another which could cause problems for the end user. COM AQUA TL UM REV. 02 AQUA TL...
  • Page 27: Chair Tilt

    ‘zero’ position the attendant should grasp the stroller trigger handle and pull on the trigger while pulling the handles up. The commode should return to the ‘zero’ position with minimal Figure 8 effort. COM AQUA TL UM REV. 02 AQUA TL...
  • Page 28: Seat To Floor

    STF – FRONT STF – REAR COMMODE TYPE (INCHES) CASTER HOLE (INCHES) 20.00 20.00 ATTENDANT PROPELLED 20.75 20.75 ATTENDANT PROPELLED 21.50 21.50 ATTENDANT PROPELLED TABLE 1 COM AQUA TL UM REV. 02 AQUA TL...
  • Page 29: Anti-Tippers

    Adjusting the anti-tipper in and out by sliding it back and forth to set the appropriate anti-tipper position. Tighten the knob and make sure it is screwed tightly to avoid anti- tipper slipping out and accidently changing position COM AQUA TL UM REV. 02 AQUA TL...
  • Page 30: Installing And Replacing The Anti Maintenance

    In some circumstances, it may be necessary to return your out. wheelchair to Future Mobility for repairs. Use multipurpose disinfectant to spray seat, scrub with soft brush if needed. Test an inconspicuous area first for color-fastness. COM AQUA TL UM REV. 02 AQUA TL...
  • Page 31 Do not use cleaning products without consulting the products’ once a month instructions and taking appropriate precautions for human Protect the paint with a coat of non-abrasive auto exposure to chemicals. wax every three months. Axles and Pivot Joints COM AQUA TL UM REV. 02 AQUA TL...
  • Page 32: Warranty

    Future Mobility Healthcare Inc. guarantees the wheelchair components to be free of defects in material and workmanship for two years. FOR (90) DAYS Cushion and Back Upholstery Future Mobility Healthcare Inc. guarantees the wheelchair cushion and back upholstery to be free of defects in material and workmanship for 90 days. COM AQUA TL UM REV. 02 AQUA TL...
  • Page 33: Limitations

    FMHI shall not be liable for any consequential or incidental damages whatsoeve COM AQUA TL UM REV. 02 AQUA TL...
  • Page 34 Cut below this line # Warranty Registration Form To validate your Future Mobility HealthCare warranty, please complete the below form and return it the address at the end of this form. Visit online at www.futuremobility.ca for more Future Mobility Products. Name: ____________________________ Street Address: ____________________________________________________ City/Country/Postal Code: ________________________________________________...