SETTING PARAMETER

1> Parameter1
Inverter Parameter
First, stop the inverter, then press the
Display
P 00
P 01
P 02
P 03
P 04
P 05
P 06
P 07
P 08
P 09
P 10
P 11
P 12
P 13
Over-Voltage application Rate
P 14
Low-Voltage application Rate
P 15
P 16
P 17
2> Parameter2
Booster Parameter
First, stop the inverter, then press the
Display
B 00
B 01
B 02
B 03
B 04
B 05
B 06
B 07
B 08
B 09
B 10
B 11
B 12
B 13
The initial operation status
B 14
B 15
B 16
B 17
and
Description
Max Frequency
Max Voltage Frequency
Max Voltage
Mid-Point Frequency
Mid-Point Voltage
Min Frequency
Min Voltage
ACC Time
DEC Time
Stop Mode
Pump HP
Overload Rate
Overload Time
Carrier Frequency
TEST
Version information
and
Description
Set Press
Run deviation
Sensor type
Sensor Adjust
Low press
Stop Time of
Low press
Low Current
Stop Time of
Low Current
Pump Direction
P
I
D
Auto Reset
-
-
-
Version information
button stimultaneously.
Value
5.0 ~ 70.0 Hz
5.0 ~ 70.0 Hz
50 ~ 240 VAC
5.0 ~ 70.0 Hz
3 ~ 220 VAC
0.1 ~ 20.0 Hz
3 ~ 100 VAC
3.0 ~ 99.9 Sec
3.0 ~ 99.9 Sec
0 : Deceleration to stop
1 : Coast to stop
0 : 1 HP (3.1A)
1 : 1.5 HP (4.3A)
50 ~ 200 %
2.0 ~ 99.9 Sec
100 ~ 200 %
50 ~ 90 %
3.0 ~ 15.0 Hz
444 - Reset setting
422 - Reset for 220VAC
424 – Reset for 240VAC
button stimultaneously.
Value
0.3 ~ 6.0 Bar
-3.0 ~ -0.2 Bar
1.0 ~ 16.0 Bar
-9.9 ~ 9.9 Bar
0.2 ~ 2.0 Bar
0 : Not use
1 ~ 999 Sec
0.5 ~ 5.0 A
0 : Not use
1 ~ 999 Sec
0 : CW 1 : CCW
1 ~ 200
1 ~ 200
1 ~ 200
0 ~ 20 ( OC,OL,OV,LV inverter err only)
0:Stop, 1:Run, 2:Last Key state
1, XX
Default (240V)
50
50
240
25
120
1.5
15
3
3
1
2
150
10
120
60
8
428
Default (240V)
3.5
-0.5
16
0
0.5
20
3.3
10
0
25
40
40
5
2