Sanwa KDP10 Instruction Manual

Voltage detector supporter

Advertisement

Quick Links

KDP10
VOLTAGE DETECTOR SUPPORTER
INSTRUCTION MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Sanwa KDP10

  • Page 1 KDP10 VOLTAGE DETECTOR SUPPORTER INSTRUCTION MANUAL...
  • Page 2: Safety Precautions

    [1] SAFETY PRECAUTIONS - Read Before Use - Thank you for purchasing KDP10, a Voltage Detector Supporter for a manual cable cutter. This Voltage Detector Supporter is intended to eliminate accidents caused by an erroneous cut of a live-wire cable for a commercial power’s alternate voltage (frequency: 50 Hz/60 Hz) by being attached to a manual cable cutter.
  • Page 3: Warning Instructions For Safe Use

    1-2 Warning Instructions for Safe Use Users are obliged to follow the instructions below when using the product. DANGER Follow the instructions below. May cause a fire or an electric shock. • This product or a manual tool with the product attached is not a voltage detector.
  • Page 4: Applications And Features

    CAUTION Do not use the product near a high-field area including a transformer or high-current circuit, an electromagnetic-wave-emitting area including a wireless device or radio, or an electrostatic-charged area. Otherwise, an unwanted behavior may be detected on a detection principle. NOTICE •...
  • Page 5: Before Use

    [3] BEFORE USE 3-1 Checking the Package Rubber ring M × 2 KDP10 main unit Sensitivity control volume cover (with the main body x Rubber ring S × 2 1, spare ×2) KDP10 VOLTAGE DETECTOR SUPPORTER 本社=東京都千代田区外神田2-4-4・電波ビル 郵便番号=101-0021・電話=東京 (03) 3253-4871㈹...
  • Page 6: Installing Batteries

    Lits/flashes when the power is ON, the battery life is low, or the tool approached to the live-wire cable. Rubber ring A position at which the included rubber rings are attachment mounted when attaching the product to a tool. Sensitivity control Remove this when adjusting the sensitivity volume.
  • Page 7: How To Use

    [4] HOW TO USE DANGER This product and a manual cutter with the product attached is not a voltage detector. Use a voltage detector or multimeter for voltage detection. May cause a fire or an electric shock. Ensure that you wear a “protective equipment” before use. May cause an electric shock.
  • Page 8 Follow the procedure below to use the product. 4-1 Check the Main Body • Visual appearance check: Does the main body have flaws on its appearance due to a fall or others? • Battery life check: Is a buzz heard for approx. 4 seconds, and the LED flashes slowly after illuminated? “4-3 Checking ON/OFF of the Power”...
  • Page 9 4-3 Checking ON/OFF of the Power Turn ON-OFF the power to check if the buzzer and LED are working correctly. * Refrain from using the product when a failure has been found. 1) Turn the power ON Press the power slide switch (ON) and identify that the power indicator is red.
  • Page 10 4-4 Checking for a normal detection Check that the product works normally with the tip of the manual cutter 1 to 2 cm away from the known live-wire cable after the product is powered ON. * Grip the cutter so that your hand touches the electrode part inside the product.
  • Page 11: Maintenance

    4-6 Using the Tool for Work Approach the cable cutter with the product attached to the live-wire cable. * If you hear a buzz and the LED flashes, stop cutting the cable. Use a voltage detector or multimeter to check if it is a live-wire or not, then resume the work.
  • Page 12 WARNING Make sure that the power is turned OFF before replacing the battery. “4-3 Checking ON/OFF of the Power” 1) Push the knob on both sides of the battery holder to pull out the battery holder, then remove two coin batteries. * Pull out the battery holder with the product upside down.
  • Page 13: Troubleshooting

    [6] TROUBLESHOOTING Status What to check The power does Is the polarity of a battery correct? not turn ON “5-2 Replacing the Batteries” Is the battery life low? “When the battery is exhausted” in “[3] Before Use” Unable to detect Is the product used under conditions where detection live-wires is not possible?
  • Page 14: After-Sale Service

    (1) year from the date of purchase. This warranty policy is valid within the country of purchase only, and applied only to the product purchased from Sanwa authorized agent or distributor. Sanwa reserves the right to inspect all warranty claims to determine the extent to which the warranty policy shall apply.
  • Page 15: Specifications

    [8] SPECIFICATIONS Item Range Detectable voltage level Approx. AC 60 V to 600 V exclusively for 50 (representative value) Hz/60 Hz (when attached to a 7”/8” cutter’s handle) Target cable Sheathed cable (unshielded cable) Operation check Intermittent buzz/LED illumination Operation indicator Intermittent buzz/LED illumination Power supply LR44 (alkali-coin battery) 1.5 V ×...
  • Page 16 本社=東京都千代田区外神田2 - 4 - 4・電波ビル 郵便番号=101 - 0021・電話=東京 (03) 3253 - 4871㈹ 大阪営業所=大阪市浪速区恵美須西2 - 7 - 2 郵便番号=556 - 0003・電話=大阪 (06) 6631 - 7361㈹ Dempa Bldg., 4-4 Sotokanda 2-Chome, Chiyoda-Ku,Tokyo, Japan 02-1709 2040 2040C Vegetable-oil-based ink is used for this document.