Goodman ARUF**14 Series Installation & Operating Instructions Manual page 22

Hide thumbs Also See for ARUF**14 Series:
Table of Contents

Advertisement

Wiring Diagrams
WARNING
ASPT**14**/ASUF**14**
COPPER POWER SUPPLY
(USE RATING PLATE)
USE MIN. 75 C FIELD WIRE
IF REPLACEMENT OF THE ORIGINAL WIRES
SUPPLIED WITH THIS ASSEMBLY IS NECESSARY,
USE WIRE THAT CONFORMS TO THE NATIONAL
ELECTRIC CODE.
NOTES:
1. RED WIRES TO BE ON TRANSFORMER TERMINAL "3" FOR 240 VOLTS AND ON
TERMINAL "2" FOR 208 VOLTS.
2. SEE COMPLETE WIRING DIAGRAMS IN INSTALLATION INSTRUCTIONS FOR
PROPER LOW VOLTAGE WIRING CONNECTIONS.
3. CONFIRM SPEED TAP SELECTION IS APPROPRIATE FOR APPLICATION. IF
SPEED TAP NEEDS TO BE CHANGED, CONNECT PURPLE WIRE FROM TERMINAL
4 OF CR RELAY TO APPROPRIATE TAP AT TB
4. BROWN AND WHITE WIRES ARE USED FOR HEAT KITS ONLY.
5. FUSE: 3A, 250V, 3AG CARTRIDGE FUSE.
6. LOW VOLTAGE FIELD WIRING TO BE N.E.C CLASS 2 WIRES.
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING.
MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO
MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
SEE
NOTE 4
SEE
NOTE 1
ALTERNATE HEAT RELAY
22
208/240 VOLTS
L1
PLF
1
EM
PLM
1
L G N
SEE NOTE 1
1
2
3
TR
B
4
24V
5
FUSE
6
5
4
PLM
HOLDER
(OPTIONAL)
R
C G
W1
W2
Y1
Y2
O
DH
1
3
1
ALTERNATE HEAT RELAY
COMPONENT CODE
WIRING CODE
FACTORY WIRING
CR
CONTROL RELAY
HIGH VOLTAGE
EM
EVAPORATOR MOTOR
LOW VOLTAGE
FL
FUSE LINK
FIELD WIRING
PLF
FEMALE PLUG CONNECTOR
HIGH VOLTAGE
PLM
MALE PLUG CONNECTOR
LOW VOLTAGE
R
RELAY
TERMINAL BOARD
TB
TR
TRANSFORMER
TL
THERMAL LIMIT
L2
PLF
2
PLM
2
1
4
7
A
CR
1
2
3
4
5
3
4
2 5
5
2
4
CR
COLOR CODE
BK
BLACK
RD
RED
YL
YELLOW
BL
BLUE
GR
GREEN
PU
PURPLE
BR
BROWN
WH
WHITE
0140A00243-A
EM
C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents