Z-5R Web
Z-5R WEB Ethernet / Wi-Fi / 3G / 4G network controller
1. OVERVIEW
Z-5R WEB Controller is used in Access Control Systems (ACS) to control a single access point.
The controller can work in standalone or network mode.
When in standalone mode, the keys are stored into database by a Master key.
In network mode, external control software is needed to operate the controller and to store keys into
database. The software also allows reading event logs, setting controller time and define valid access time
of the day for each card.
To operate in network mode, the controller is connected to network via Ethernet or Wi-Fi network adapters.
In network mode, if the connection to control software is lost, the controller still continues to work as
standalone, storing the events in the local event buffer.
Authorisation through the access points is made basing on the status of known tokens: proximity cards,
Touch Memory keys, or PIN codes. All these tokens will be hereafter called simply "keys".
By function, the keys fall into Access keys and Programming keys categories. Access keys, in turn, can be
Normal and Blocking. Blocking keys have more rights than Normal keys.
In Normal mode, the controller grants access to both Normal and Blocking keys.
In Blocking mode, access is granted for Blocking keys, but denied for Normal Keys.
Usage example: all general employees are issued Normal keys, and security department – Blocking keys.
During working hours, the controller is in Normal mode, and all employees are granted access. Out of
hours, Blocking mode is activated and only security has access.
Master keys are the keys that program the controller. They only work for standalone controller
programming, and cannot be used for access.
Master keys allow to:
-
Add and erase Normal, Blocking and other Master keys;
-
Set time for opening signal on locking device (access control);
-
Activate and deactivate Accept Mode.
In Accept Mode, any key is granted access but also is stored into controller memory as a Normal key. This
mode helps to recover the keys database if a new ACS is being installed on a customer site where access
keys have already been issued. In this case, the controller is put into Accept Mode for some time, allowing
it to keep collecting and storing keys into its memory. Then, when the controller is reverted to Normal
mode, only already stored keys will be granted access.
To collect keys codes, the controller supports operation with two readers (one for entry and one for exit) by
Wiegand (-26, -34, -42 or -50), or iButton (Dallas Touch Memory) protocols. Each reader uses its own
separate key database in controller memory. After access is granted to the key, the controller issues a
control signal (opening/closing a transistor) to the locking device (electromechanical or electromagnetic lock
or latch, turnstile or barrier). Locking device type and connection protocol are selected during controller
configuration.
The controller allows storing up to 8,192 events in its circular log buffer. Events include: code gained, door
sensor operated, control signal issued, etc.
To improve functionality the Controller allows to:
- Connect a door sensor to generate "Door passed" event and to reduce the "Door unlocked" alarm
duration (and reducing the locking device unlocked signal duration).
- Connect a door release ("exit") button to open the door without need for authorisation. Connect an
external emergency unlock signal, so that the door can be opened in emergency.
User Manual
www.ironlogic.me
Page 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the Z-5R Web and is the answer not in the manual?

Questions and answers

Summary of Contents for ironLogic Z-5R Web

  • Page 1 User Manual 1. OVERVIEW Z-5R WEB Controller is used in Access Control Systems (ACS) to control a single access point. The controller can work in standalone or network mode. When in standalone mode, the keys are stored into database by a Master key.
  • Page 2: Specifications

    Z-5R Web www.ironlogic.me 2. SPECIFICATIONS Keys memory 2x 8168 keys Events memory 8192 events Attached readers Wiegand (-26, -34, -42, -50), Reader protocols iButton™ Reader indication control Red and Green LEDs, Audible Beep Readers supply protection 200 mA Power output current...
  • Page 3 Z-5R Web www.ironlogic.me 3. CONNECTION The controller dimensions are presented on this Figure: Caution: To avoid sharp edges in controller casing, use saw to remove the tabs covering holes for leading wires through, rather than breaking the tabs out manually.
  • Page 4 Z-5R Web www.ironlogic.me Controller Terminal Layout socket Block of Ethernet power plugs Block of plugs Block of of management plugs of of indication sensors The block of Block of plugs for information connection of plugs readers Terminals designation table Power Terminals Group...
  • Page 5 Z-5R Web www.ironlogic.me Reader Connection Terminals Group Designation Purpose DATA1 Wiegand mode: DATA1 for reader input and DATA0 for reader output. iButton™ mode: reader output signal wire (TM). GROUND Reader common wire connection. DATA0 Wiegand mode: DATA0 for reader input and DATA1 for reader output.
  • Page 6 4. CONFIGURATION Important: When configuring Z-5R WEB controller, note that it actually consists of two functional modules: an ACS controller itself, and a network connection module. The network connection module allows for: 1) Controller connection to the on-site LAN, via any of the following interfaces: Ethernet, Wi-Fi or USB modem.
  • Page 7 Z-5R Web www.ironlogic.me • Server connection mode. The connection module is listening for incoming TCP/IP connections from the PC running control software (such as GuardLight, GuardCommander, Avantgarde (Авангард)). Ethernet Ethernet Internet • Client connection mode. The connection module attempts to connect to control software via TCP/IP.
  • Page 8: Web Interface

    Z-5R Web www.ironlogic.me ZProxy Server (available at zproxy.con.ru) allows the (proxied) connection between controller and the control software, where direct connection is impossible, e.g. if the controller and the software are in different LANs. If Internet access is available, 1) the controller connects to ZProxy server, 2) the control software connects to that server too, and 3) using a password, the control software requests connection to the required controller.
  • Page 9 5. 1. Go through appearing menu tab by tab, and configure parameters on each tab. Please save the changes on each tab! Later, when configuration is complete and Z-5R WEB is connected to on-site LAN (on-board jumper is set into NORMAL or LOCK), the configuration Web interface will still be available by the IP address which will either be manually assigned during initial configuration, or automatically acquired from DHCP server when registering onto the on-site LAN.
  • Page 10 Z-5R Web www.ironlogic.me LEGEND: Time Elapsed: time elapsed since the controller powered up. Connection: LAN connection mode abbreviation (e.g. ETH for Ethernet etc.) Mode: Controller operation mode (Web, Server, Client, Standalone). Connected: In Client and Server operation modes, shows IP address of connected PC running the control software.
  • Page 11 Z-5R Web www.ironlogic.me Static IP: A unique IP address assigned to the controller. Network Mask: Subnet mask for this LAN segment. Default Gateway: IP address of the gateway leading to other networks, including Internet. DNS Server: The DNS server IP address.
  • Page 12 Z-5R Web www.ironlogic.me To select a network, highlight it in the list and press Select button. When selected, SSID and security type for that network are displayed in settings area. If network security is enabled, enter the security key as well.
  • Page 13 After setup is complete, save the parameters by pressing Save button. Control Software Connection Mode Tab If Z-5R WEB is intended to work in network mode, i.e. under external software control, then after completing LAN connection configuration, it is also necessary to set up the connection mode between connection module and control software.
  • Page 14 Z-5R Web www.ironlogic.me Server Address: DNS name or IP address of the cloud service Web server, where the controller should connect. Port: The port on which the cloud Web server is listening. Path: The path to data processing file on the cloud Web server.
  • Page 15 Z-5R Web www.ironlogic.me 5.4.3 Client In Client connection mode, the connection module attempts regularly to establish connection to the control software. Also select this mode, if the controller connects to a ZProxy server. The following parameters need to be provided:...
  • Page 16 Z-5R Web www.ironlogic.me Where: Accept Mode: Activates Accept mode, where all new keys will be stored into memory as Normal keys. Add Keys Mode: Activates Add Normal and Blocking Keys mode on the controller. See paragraph 7.1 for details. Add Master Keys Mode: Activates Add Master Keys mode. See paragraph 7.2 for details.
  • Page 17 NORMAL or LOCK, go to Advanced Settings tab and choose the Reboot Controller function there. 6. POWER-UP AND GETTING STARTED. Connect external devices to your controller as per Chapter 3. Factory default settings for Z-5R WEB module are as follows: Use DHCP server;...
  • Page 18 Z-5R Web www.ironlogic.me 7. SETTING UP CONTROLLER WITH A MASTER KEY. To manage the controller with a Master key (i.e. to switch into required programming mode to create or erase a Normal or Blocking card, activate Accept Mode, etc.), two types of Master key touches are used.
  • Page 19 Z-5R Web www.ironlogic.me 7.3 Erase Normal Keys Mode Touch the reader shortly twice with a Master key. The controller will emit a short beep acknowledging the Master key. On second touch, the controller will emit two short beeps denoting second Master key touch in programming mode. No later than 6 s after that, touch and hold the Master key at the reader (long touch).
  • Page 20: Package Contents

    (e.g. Guard Commander) over the network, then please use the Web interface to configure the controller for network operation. 9. PACKAGE CONTENTS. - Z-5R WEB controller -1 - Mounting kit -1 - CR2032 (watch-type) battery -1 10. OPERATING CONDITIONS Ambient temperature: 5°C…40°C...
  • Page 21: Limited Warranty

    Z-5R Web www.ironlogic.me 11. LIMITED WARRANTY. This device is covered by a limited warranty for 24 months. The warranty becomes void if: - This Manual is not followed; - Device has physical damage; - Device has visible traces of exposure to moisture and aggressive chemicals;...