Alfa Laval 9611-99-5750 Mounting Instructions
Alfa Laval 9611-99-5750 Mounting Instructions

Alfa Laval 9611-99-5750 Mounting Instructions

Indication unit for lkla o85, pnp, standard pinout zz0496

Advertisement

Quick Links

Mounting instructions
9611-99-5750, Indication unit for LKLA ø85, PNP, Standard pinout (ZZ0496)

Items supplied

1 x puck E17013
1 x inductive double sensor IN5225
2 x hexagon head screws
4 x washers

Wiring (PNP, Standard pin connection)

Closed: OUT +1 (A1) Pin 4
Open: OUT +2 (A2) Pin 2

Electrical design

Operating voltage

Output function

Current consumption

Current rating

Ambient temperature

Protection rating

► Loosen the screws (1) and remove the
angle bracket.
► Mount the puck as shown (2).
► Attach the puck and the angle bracket (3).
Pointer showing to the right: Valve is closed.
The drawing on the right shows basically an
NC (Normally Closed) valve.
Puck pointer must therefore be installed to the
right so that it follows the valve closed direc-
tion.
► Keep a distance of approx. 2 mm between
puck and angle bracket.
Note: Most of the actuators are delivered with
a coupling provided with a rim. It ensures
the right distance between puck and angle
bracket.
► Tighten the screws (1).
► Tighten opposite grub screws (2) on the
puck, tightening torque 2 Nm.
DC PNP
10...36 V DC
2 x NO
< 15 mA
250 mA
-25...80 °C
IP 67
Alfa Laval Kolding A/S, www.alfalaval.com
1 BN
4 BK
2 WH
4:
A1
3 BU
2:
A2
3
2
1
L +
2
1
3
4
L
1
2 mm
1
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 9611-99-5750 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Alfa Laval 9611-99-5750

  • Page 1 Mounting instructions 9611-99-5750, Indication unit for LKLA ø85, PNP, Standard pinout (ZZ0496) Items supplied 1 x puck E17013 1 x inductive double sensor IN5225 2 x hexagon head screws 4 x washers Wiring (PNP, Standard pin connection) Closed: OUT +1 (A1) Pin 4...
  • Page 2 (1) and tighten the screws, tightening torque 2 Nm. < 1,5 mm 1 ► Check the feedback for the valve states NC valve (open and closed). Indication via LED and visual pointer position. Valve closed Valve open Alfa Laval Kolding A/S, www.alfalaval.com...