Mounting instructions
9611-99-5750, Indication unit for LKLA ø85, PNP, Standard pinout (ZZ0496)
Items supplied
1 x puck E17013
1 x inductive double sensor IN5225
2 x hexagon head screws
4 x washers
Wiring (PNP, Standard pin connection)
Closed: OUT +1 (A1) Pin 4
Open: OUT +2 (A2) Pin 2
Electrical design
Operating voltage
Output function
Current consumption
Current rating
Ambient temperature
Protection rating
► Loosen the screws (1) and remove the
angle bracket.
► Mount the puck as shown (2).
► Attach the puck and the angle bracket (3).
Pointer showing to the right: Valve is closed.
The drawing on the right shows basically an
NC (Normally Closed) valve.
Puck pointer must therefore be installed to the
right so that it follows the valve closed direc-
tion.
► Keep a distance of approx. 2 mm between
puck and angle bracket.
Note: Most of the actuators are delivered with
a coupling provided with a rim. It ensures
the right distance between puck and angle
bracket.
► Tighten the screws (1).
► Tighten opposite grub screws (2) on the
puck, tightening torque 2 Nm.
DC PNP
10...36 V DC
2 x NO
< 15 mA
250 mA
-25...80 °C
IP 67
Alfa Laval Kolding A/S, www.alfalaval.com
1 BN
4 BK
2 WH
4:
A1
3 BU
2:
A2
3
2
1
L +
2
1
3
4
L
1
2 mm
1
2
Need help?
Do you have a question about the 9611-99-5750 and is the answer not in the manual?
Questions and answers