Online Calibration Of Multipoint Adjustment Channels - Bosch DDU 9 Manual

Hide thumbs Also See for DDU 9:
Table of Contents

Advertisement

13 | Online Measurement
13.4 Online calibration of multipoint adjustment
108 / 148
channels
Example: measurement of wheel force
– Physical property 'wheel force' not directly measureable
– Load transfer through suspension kinematics
– Physical value at sensor position defined by vehicle
– Curve definition by online adjustment at vehicle
Force at sensor
Force at wheel
1.
Create a multipoint adjustment measurement channel. To create a multipoint channel,
see chapter 'Configuring a multipoint adjustment'.
2.
Download the configuration on the DDU 9. To connect the DDU 9 to RaceCon, see
chapter 'Connecting the Unit to RaceCon'.
3.
Click on the desired channel in the DDU 9 Project Tree.
4.
Double-click on a measurement channel in the Data Area to open the online view.
Click to open
measurement
channels in
data view
Double-
click to
open
online view
5.
Click on 'Calibrate adjustment points' to open calibration window.
6.
Apply the desired physical condition to the sensor (e.g. by applying a force on the
wheel).
DDU 9
Analog and
physical value
Click to open
calibration
window
Bosch Motorsport

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents