Bosch DDU 9 Manual page 107

Hide thumbs Also See for DDU 9:
Table of Contents

Advertisement

13.3.4 Triggering the group adjustment
Bosch Motorsport
Double-click
to open
group
adjustment
overview
The selected measurement channels are added to the group adjustment event.
1.
Connect the input pin to GND using a push-button.
2.
Make sure the pullup-resistor is enabled, if you selected 'active low' trigger polarity.
3.
Double-click on the input channel 'grp_adj_channel' of the group adjustment.
4.
Download the configuration on the DDU 9. To connect the DDU 9 to RaceCon, see
chapter 'Connecting the Unit to RaceCon'.
5.
Open a measurement sheet by clicking on the desired measurement sheet in the Pro-
ject Tree.
6.
Drag the 'grp_adj_channel' and the 'input_grp_adj_channel' to the online measure-
ment sheet.
7.
Press and release the push-button.
8.
The measurement labels indicate the state of the input pin and the state of the ad-
justment.
Drag channels
on
Measurement
Sheet
NOTICE
A display alarm can be linked to the trigger channel to indicate that
the trigger has been detected.
DDU 9
Online Measurement | 13
Check box to add
channel to group
adjustment
Voltage at
input pin
State of adjustment
0 – Idle
1– Adjustment
triggered
2 – Adjustment lock
time
107 / 148