Alarm
Description
NTC probe for wash cycle
E74
improperly positioned
E83
Error in reading selector
Recirculation pump / Motor fan triac
E84
sensing failure
Recirculation pump / Motor fan triac
E85
alarm
E86
Selector configuration error
Display board microprocessor
E87
faulty
Communication error between
E91
main PCB and display
Communication inconsistency
E92
between main PCB and display
(incompatible versions)
E93
Appliance configuration error
Incorrect configuration of washing
E94
cycle
Inconsistency between programme
E97
selector and cycle configuration
E98
FCV_MB protocol incong. Error
E9C
Display board configuration error
E9E
UI touch fault
EA1
DSP system failure
EA6
DSP door open failure
EB1
Power supply frequency out of limits Wrong or disturbed Power Supply line. Main board defective
(EH1)
EB2
Power supply voltage too high
(EH2)
EB3
Power supply voltage too low
(EH3)
EB4
Zero Watt relay alarm
(EH4)
EBD
Heater WD relay sensing alarm
(EHD)
Technical Support - MDM
Possible fault
Wiring faulty; NTC probe for wash cycle improperly positioned;
NTC probe faulty; Main PCB faulty.
Main PCB faulty (incorrect configuration data).
Main board defective
Recirculation pump or motor fan defective; Wiring or main board
defective
Display board.
Display board.
Wiring faulty; Control/display PCB faulty;
Main circuit board faulty.
Incorrect control/display PCB;
Incorrect PCB (does not correspond to the model).
Main PCB faulty (incorrect configuration data).
Main PCB faulty (incorrect configuration data).
Main PCB faulty (incorrect configuration data).
Main board incompatible with FCV control board
Display board faulty.
Display Board
Wiring or main board defective; DSP sensor failure; Main motor belt
broken
Wiring or main board defective; DSP sensor failure; Main motor belt
broken; Lid open
Wrong or disturbed Power Supply line. Main board defective
Wrong or disturbed Power Supply line. Main board defective
Main board defective
Main board defective
64/97
Machine status/action
The heating phase is skipped
Cycle cancelled
Safety Drain cycle.
Cycle stops with door unlocked
Safety Drain cycle.
Cycle stops with door unlocked
----------------
No action to be taken
----------------
Cycle blocked
Cycle blocked
Cycle blocked
Cycle blocked
Cycle blocked
----------------
No actions
Skip of the drum positioning phase
Cycle paused
Wait for nominal power supply
conditions
Wait for nominal power supply
conditions
Wait for nominal power supply
conditions
No actions
Cycle blocked
with door locked
Reset
RESET
START/RESET
RESET
RESET
START
ON/OFF
RESET
START
ON/OFF
RESET
RESET
ON/OFF
ON/OFF
ON/OFF
RESET
OFF/ON
START
ON/OFF
RESET
OFF/ON
START/RESET
START/RESET
OFF/ON
OFF/ON
OFF/ON
OFF/ON
RESET
RESET
599 76 11-68 Rev. 01