p50716
BI: CUD analog input 1 signal source for enable / CUD AI 1 ena s_src
DCP_CTRL
Can be changed: T
Data type: Unsigned32 / Binary
Min
-
Description:
Sets the signal source to enable analog input 1 (AI 1, X177.27/28) on the CUD.
Note:
AI: Analog Input
p50721[0...n]
CUD analog input 2 scaling / CUD AI 2 scal
DCP_CTRL
Can be changed: U, T
Data type: FloatingPoint32
Min
-1000.0 [%]
Description:
Sets the scaling for analog input 2 (AI 2, X177.29/30) on the CUD.
The value indicates the percentage value for mapping an input voltage of 10 V at the analog input.
Example:
p50721 = 90%
--> 10 V is scaled to 90%
--> 5 V corresponds to 45%
Note:
AI: Analog Input
p50722
CUD analog input 2 offset / CUD AI 2 offs
DCP_CTRL
Can be changed: U, T
Data type: FloatingPoint32
Min
-200.00 [%]
Description:
Sets the offset for analog input 2 (AI 2, X177.29/30) on the CUD.
Note:
AI: Analog Input
p50723
CUD analog input 2 signal processing / CUD AI 2 sig proc
DCP_CTRL
Can be changed: T
Data type: Integer16
Min
0
Description:
Sets the signal processing mode for analog input 2 (AI 2, X177.29/30) on the CUD.
Value:
0:
1:
2:
3:
Note:
AI: Analog Input
p50724
BI: CUD analog input 2 inversion / CUD AI 2 inv
DCP_CTRL
Can be changed: T
Data type: Unsigned32 / Binary
Min
-
Description:
Sets the signal source for inverting the signal from analog input 2 (AI 2, X177.29/30) on the CUD.
1 signal: inversion
0 signal: no inversion
Note:
AI: Analog Input
SINAMICS DCP
List Manual (LH21), 05/2016
Signal not influenced
Signal absolute value generation
Signal inverted
Signal absolute value generation inverted
Siemens Parts
Max
-
Max
1000.0 [%]
Max
200.00 [%]
Max
3
Max
-
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 2080
Factory setting
1
Access level: 3
Func. diagram: 2080
Factory setting
100.0 [%]
Access level: 3
Func. diagram: 2080
Factory setting
0.00 [%]
Access level: 3
Func. diagram: 2080
Factory setting
0
Access level: 3
Func. diagram: 2080
Factory setting
0
247