r3115[0...63]
Fault drive object initiating / F DO initiating
TM150, TM15DI_DO,
Can be changed: -
TM31
Data type: Integer32
Min
-
Description:
Displays the drive object number of the initiating drive object for this fault as integer number.
Value = 63:
The fault was initiated by the drive object itself.
Dependency:
Refer to: r0945, r0947, r0948, r0949, r2109, r2130, r2133, r2136, r3120, r3122
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
The structure of the fault buffer and the assignment of the indices is shown in r0945.
p3116
BI: Acknowledgement automatically suppressed / Ackn suppress
CU_DCP
Can be changed: U, T
Data type: Unsigned32 / Binary
Min
-
Description:
Sets the signal source for the automatic acknowledgement on the device drive object.
BI: p3116 = 0 signal
Faults present are automatically acknowledged on the device drive object. Local device faults are forwarded to the
first active drive object.
BI: p3116 = 1 signal
Faults present are not automatically acknowledged on the device drive object. Local device faults are not forwarded.
Dependency:
Refer to: p2102, p2103, p2104, p2105, p3981
Note:
When selecting a standard telegram, the BICO interconnection for control signal STW1.10 (master control by PLC) is
automatically established.
r3120[0...63]
Component fault / Comp fault
All objects
Can be changed: -
Data type: Unsigned32
Min
-
Description:
Displays the component of the fault which has occurred.
Dependency:
Refer to: r0945, r0947, r0948, r0949, r2109, r2130, r2133, r2136, r3122
Note:
Value = 0: Assignment to a component not possible.
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
The structure of the fault buffer and the assignment of the indices is shown in r0945.
r3121[0...63]
Component alarm / Comp alarm
All objects
Can be changed: -
Data type: Unsigned32
Min
-
Description:
Displays the component of the alarm which has occurred.
Dependency:
Refer to: r2110, r2122, r2123, r2124, r2125, r2134, r2145, r2146, r3123
Note:
Value = 0: Assignment to a component not possible.
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
The structure of the alarm buffer and the assignment of the indices is shown in r2122.
SINAMICS DCP
List Manual (LH21), 05/2016
Siemens Parts
Max
-
Max
-
Max
-
Max
-
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 8050, 8060
Factory setting
-
Access level: 3
Func. diagram: 8060
Factory setting
0
Access level: 3
Func. diagram: 8060
Factory setting
-
Access level: 3
Func. diagram: 8065
Factory setting
-
119