EN
Connecting to a "T" union of the drain circuit
1.
Connect the dishwasher drain hose (ref. A fi g. 5-11) to the "T" union (ref. B
fi g. 5-11) of the drain circuit using a 38 to 50 mm (1-1/2 to 2") screw clamp*
(ref. C fi g. 5-11); if necessary, cut the end of the dishwasher drain hose (ref.
D fi g. 5-11) (do not cut the corrugated section).
* Available from any plumbing stockist
20
INSTALLATION INSTRUCTIONS
MAKE THE CONNECTION UPLINE FROM THE SIPHON OF THE
DRAIN LINE AND AT LEAST 400 mm (15-3/4") ABOVE THE FLOOR
ON WHICH THE DISHWASHER WILL BE INSTALLED.
B
C
A
D
Fig. 5-11