  • Page 1 Control panel FA01078-EN for 230Vgearmotors ZA3N EN English INSTALLATION MANUAL...
  • Page 2 Any other use is dangerous. CAME S.p.A. is not liable for any damage caused by improper, wrongful and unreasonable use. • Before installing the control panel, make sure that the gui-...
  • Page 3 • All maintained-action switches that are connected to the control panel must be po- sitioned so that the maneuvering area is completely visible from the switches, yet far enough away from any moving parts. • Make sure that the operator has been properly adjusted and that any associated safety and protection devices, as well as the gearmo- tor's manual release, are working properly.
  • Page 4: Technical Data

    The photocells, afterdetecting an obstruction, may trigger: - reopening ifthe gate is closing; Intended use Model Operator ZA3N ATI - FAST - FERNI - FROG - KRONO Any installation and/or use other than that specified in this manual is forbidden. Technical data Fuse table...
  • Page 5: Description Of Parts

    Description of parts Connection terminals and, the partial opening Control board fuses Functionsselector with ten DIP-switches Fuse for control devices and accessories Radio-frequency card slot(see table) LED warningthat 24 V are running Alert LED Radiocode memorizing buttons Torque limiter Trimmerfor adjusting the operating time Condensers* Trimmer for adjusting the automatic closing time Trimmer for adjustingthe closing delay on motor 2,...
  • Page 6: Installation

    Cable type and minimum section cable length Connection < 20 m 20 < 30 m Control panel power-supply 3G x 1.5 mm 3G x 2.5 mm Motor power supply 4G x 1.5 mm 4G x 2.5 mm Signaling devices 2 x 0.5 mm2 Command and control devices 2 x 0.5 mm2 Safety devices (photocells)
  • Page 7: Input Voltage

    M2 - Gearmotor with E E3 delayed opening. delayed closing. Came gearmotors standard opening scheme setup. gearmotor to W X Y (M2) regardless of which side it is fi tted on (for FROG, if necessary, invert the X and Y connections).
  • Page 8 Warning and lighting devices Gate open warning-light - For warning that the gate is open. It stops fl ashing when the gate closes. Movement warning fl ashing-light - Itfl ashes when the gate is opening and closing. CONTACTS rated for 230V - 25W max.
  • Page 9: Safety Devices

    Safety devices Delta Dir/DeltaS Connection for reopening during closing (N.C. contact). - With safety devices such as photocells, sensitive safety- edges or other devices. During closing, the contact triggers an inversion of movement until the gate is completely open. If unused, set DIP-switch 9 to ON. <- C1 ->...
  • Page 10 Features selection 1 ON Automatic closing enabled (1 OFF-disabled); 2ON “Open-stop-close-stop” with button (2-7) and radio control (with AF card fi tted) enabled; 2 OFF “Open-close”with button (2-7) and radio control (with AF card fi tted) enabled; 3 ON "Only open" with radio control (with AF card fi tted) enabled; (3 OFF-disabled); 4 ON Pre-fl...
  • Page 11 ENABLING THE RADIO CONTROL Antenna and AF radiofrequency card Connect the RG58 antenna-cableto the corresponding terminals. Fit the radio-frequency card intothe slot on the control board AFTER CUTTING OFF THE MAINS POWER SUPPLY. N.B.: The control board recognizes the radiofrequency card only when it is powered up.
  • Page 12: Final Operations

    These must therefore be disposed of by authorized, certified professional services. DISPOSE OFRESPONSIBLY! REFERENCE REGULATIONS CAME SpA declares that this product complies with the current directives at the time it is manufactured. The contents of this manual may change, at any time, and without notice. CAME S.p.A.