Download Print this page

Electrical Connections - Smeg SE32X Instruction Manual

Instructions and advice for the use, installation and maintenance

Advertisement

6) ELECTRICAL CONNECTIONS

Electrical connection must be carried out in
compliance with the specifications and
provisions in force.
Before proceeding with the connections, check that:
- the voltage rating of the appliance and the
current sockets suits the maximum power draw
of the appliance (see data label affixed to the
lower part of the appliance itself).
- The system is equipped with an efficient earth
connection in compliance with the pertinent
provisions in force. The manufacturer declines all
responsibility for failure to comply with these
provisions.
- If the appliance has no power cable, connect a
cable of adeguate section to the terminal strip
(consult the table on next page) complying with
the wiring diagram of fig. 7. This diagram is also
affixed to the hot plate.
When connection to the electricity main is made
by using a socket (gas version only):
- fit a standard plug to power cable (if supplyied).
This plug should be able to bear the load
indicated on the data label. Connect the wires
according to the diagram in fig. 7, remembering
to comply with the following instructions:
letter L (live) = brown wire;
1
letter N (neutral) = blue wire;
earth symbol
= yellow-green wire.
- The powering cable must be positioned so that it
is never able to reach an overtemperature of 65K
in any part.
- Never use reductions, adapters or shunts for the
connection since these could cause false
contacts and dangerous overheating.
- The outlet must be accessible after the built-in.
INSTALLATION
When the appliance is connected straight to the
electricity main:
- install an omnipolar cutout between the
appliance itself and the main. This circuit-breaker
should be sized according to the rating of the
appliance and the opening between its contacts
should be at least 3 mm.
- Remember that the earth wire must not be cutout
by the switch.
- Alternatively, the electrical connection may also
be protected by a high sensitivity differential
switch.
Installers are strongly advised to connect the
yellow-green earthing wire to an efficient earthing
system.
The manufacturer cannot be responsible for the
missing earthing of the appliance.
WARNINGS:
all our appliances are designed and
manufactured in compliance with European
standards EN 60 335-1 and EN 60 335-2-6 plus
the relative amendments.
The appliance complies with the provisions of
the following EEC Directives:
- CEE 89/336 + 92/31 + 93/68 regarding to
electromagnetic compatibility.
- CEE 73/23 + 93/68 regarding electrical safety.
FIG. 7
7

Advertisement

loading

This manual is also suitable for:

Pfz 02