6) ELECTRICAL CONNECTIONS

IMPORTANT!
The appliance must be installed following
the manufacturer's instructions. The
manufacturer will not be liable for injury
to persons or animals or property
damage
caused
installation.
Electrical connection must be carried out in
compliance with the specifications and
provisions in force.
Before proceeding with the connections, check
that:
- the voltage rating of the appliance and the
current sockets suits the maximum power draw
of the appliance (see data label affixed to the
lower part of the appliance itself).
- The system is equipped with an efficient earth
connection in compliance with the pertinent
provisions in force. The manufacturer declines all
responsibility for failure to comply with these
provisions.
- If the appliance has no power cable, connect a
cable of adeguate section to the terminal strip
(consult the table on next page) complying with
the wiring diagram of fig. 7. This diagram is also
affixed to the hot plate.
When connection to the electricity main is
made by using a socket (gas version only):
- fit a standard plug to power cable (if supplyied).
This plug should be able to bear the load
indicated on the data label. Connect the wires
according to the diagram in fig. 7, remembering
to comply with the following instructions:
letter L (live) = brown wire;
letter N (neutral) = blue wire;
earth symbol
= green - yellow wire.
- The powering cable must be positioned so that it
is never able to reach an temperature
of 90 °C in any part.
- Never use reductions, adapters or shunts for the
connection since these could cause false
contacts and dangerous overheating.
- The outlet must be accessible after the built-in.
When the appliance is connected straight to
the electricity main:
- install an omnipolar cutout between the
appliance itself and the main. This circuit-breaker
should be sized according to the rating of the
appliance and the opening between its contacts
should be at least 3 mm.
INSTALLATION
by
an
incorrect
- Remember that the earth wire must not be cutout
by the switch.
- The electrical connection may also be protected
by a high sensitivity differential switch.
Installers are strongly advised to connect the
yellow-green earthing wire to an efficient earthing
system.
The manufacturer cannot be responsible for the
missing earthing of the appliance.
Before performing any service on the electrical
part of the appliance, it must absolutely be
disconnected from the electrical network.
If the installation requires modifications to
the home's electrical system or if the socket
is incompatible with the appliance's plug,
have changes or replacements performed by
professionally-qualified person. In particular,
this person must also make sure that the
section of the wires of the socket is suitable
for the power absorbed by the appliance.
WARNINGS:
all our appliances are designed and
manufactured in compliance with European
standards EN 60 335-1 and EN 60 335-2-6 plus
the relative amendments.
The appliance complies with the provisions of
the following EEC Directives:
- CEE
2004/108/CE
electromagnetic compatibility.
- CEE 2006/95CE regarding electrical safety.
- CEE 2011/65/UE on the restriction of use of
certain hazardous substances.
- Regulation (EU) No. 65/2014 supplementing
Directive 2010/30/EU.
- Regulation (EU) No. 66/2014 supplementing
Directive 2009/125/EC.
Standards EN 30-2-1, EN 60350-1, EN 60350-2,
EN 50304.
8
regarding
FIG. 7
to

Advertisement

loading