Smeg PGA95SC3 Instruction Manual page 7

Smeg cooking hob instruction manual
Table of Contents

Advertisement

Instructions for the installer
2.3
Clearance above and around domestic appliances
Extract from AS5601
REQUIREMENTS
1
Overhead clearances – (Measurement A)
Range hoods and exhaust fans shall be installed in accordance with
the manufacturer's instructions. However, in no case shall the
clearance between the highest part of the hob of the cooking
appliance and a range hood be less than 600 mm or, for an overhead
exhaust fan, 750 mm.
Any other downward facing combustible surface less than 600 mm
above the highest part of the hob shall be protected for the full width
and depth of the cooking surface area in accordance with Clause
5.12.1.2. However, in no case shall this clearance to any surface be
less than 450 mm.
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pga95f3Pga95fsc3Pgfa95f-2

Table of Contents