E Checking Individual Parameters - Laars MagnaTherm MGH1600 Installation And Operation Instructions For

Modulating boiler/water heater, 1,600/1,999/2,499/3,000/3,500/4,000 mbtu/h
Table of Contents

Advertisement

MagnaTherm Boilers and Water Heaters
Reset
Figure 41. Reset Button on Controller
4.
The system will present a listing for each
group of parameters that need verification
Menu 7.
SafetyParameterConfirmation
5.
For each group, check the list carefully. Press
Yes if all of the parameters in the group have
been entered correctly. For each group, you
are given 30 seconds to select Yes/No.
A count-down timer is shown at the bottom of
the screen.
If you made changes in other safety-related
groups, verify the entries in those groups
in the same way. Do this until the following
screen shows
Menu 8.
Safety Parameter Reset
6.
When the process is complete, the system will
tell you to reset the control system. The Reset
button is located on the front of the controller.
You must press the Reset button within 30
seconds, or the verification will be cancelled.
A count-down timer is shown at the bottom of
the screen.
9.E
Checking Individual Parameters
1.
From the Home screen, press the icon for the
controller.
Menu 9.
Home screen
2.
The Status Summary page for the controller
will appear. This shows the current operating
condition of the controller, and also shows
some of the configuration settings.
See Menu 10
Page 61