5 Server Configuration

5.1 General Settings
You can configure your server through ' Configuration->General Settings'.
Pool URL- Enter the URL of your desired pool in this column.
Worker- This is your worker ID on the selected pool.
Password- This is the password for your selected worker.
Comment:
5.1.1 The R4 server can be set up with three mining pools, with decreasing priority from the
first pool (pool 1) to the third pool (pool 3). The pools with low priority will only be used if
all higher priority pools have gone offline.
5.1.2 When 'Stop running when temperature is over 80℃' is checked, the server will stop
mining when the temperature(PCB) exceeds 90℃ to protect the server. If it is unchecked, the
server will still mine even at high temperatures. Note that while the interface says 80℃ the PCB
temperature will actually go to 90℃ before the machine stops mining.
5.1.3 When "Customize the fan speed percentage" is checked, the fan speed can be controlled by
the user. If it is unchecked, the fan speed will depend on the temperature of the hash boards.
Click 'Save & Apply' to save and restart server.
Kindly reminder: Please set the fan speed above 80% to keep the temp(PCB) below 90 degrees
and the temp(chip) below 115 degrees.