Pentair Myers MES100 Installation And Operator's Manual
Pentair Myers MES100 Installation And Operator's Manual

Pentair Myers MES100 Installation And Operator's Manual

Submersible sewage ejector pump
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Installation/Operation/Parts
For further operating, installation, or
maintenance assistance:
Call 1-888-987-8677
English . . . . . . . . . .Pages 2-12
293 WRIGHT STREET, DELAVAN, WI 53115 WWW.FEMYERS.COM
PH: 888-987-8677 ORDERS FAX: 800-426-9446
490 PINEBUSH ROAD, UNIT 4, CAMBRIDGE, ONTARIO, N1T 0A5
PH: 800-363-7867 ORDERS FAX: 888-606-5484
© 2016 Pentair plc. All Rights Reserved.
MES50/MES100
Installation/Fonctionnement/Pièces
Pour plus de renseignements concernant
l'utilisation, l'installation ou l'entretien,
Composer le 1 (888) 987-8677
Français . . . . . . . .Pages 13-24
INSTALLATION AND
OPERATOR'S MANUAL
Submersible Sewage
Ejector Pump
INSTALLATION ET MANUEL
DE L'OPÉRATEUR
Pompe submersible
d'eaux d'egout
23833A704 (05/25/16)

Advertisement

Table of Contents
loading

Summary of Contents for Pentair Myers MES100

  • Page 1 Français . . . . . . . .Pages 13-24 293 WRIGHT STREET, DELAVAN, WI 53115 WWW.FEMYERS.COM PH: 888-987-8677 ORDERS FAX: 800-426-9446 490 PINEBUSH ROAD, UNIT 4, CAMBRIDGE, ONTARIO, N1T 0A5 PH: 800-363-7867 ORDERS FAX: 888-606-5484 23833A704 (05/25/16) © 2016 Pentair plc. All Rights Reserved.
  • Page 2: Table Of Contents

    Safety Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . .2 Installation .
  • Page 3: Installation

    Safety • Installation 7. Wear safety glasses at all times when working with Hazardous pressure and gas - risk of the pump. explosion and personal injury. Failure to follow the warnings that follow can result in personal injury. 8. Keep the work area clean, uncluttered and properly lighted - secure all unused tools and equipment.
  • Page 4 Installation Typical Single Phase Switch Operated Installation Typical Three Phase Simplex Installation with float...
  • Page 5: Operation

    Installation • Operation • Maintenance Operation Follow these guidelines for installation: 1. Provide properly sized pit (see Specifications) on NOTICE: Do not allow pump to run in a dry sump. sewage tank. Minimum pump run time is two Doing so will void the warranty and may damage minutes.
  • Page 6: Ground Check

    Maintenance Checking motor operation If motor is thoroughly dry, needle of ohmmeter will not move on the ground check. This indicates a reading of If the unit is being operated by float switch, unplug 50 megohms or higher. When making the ground check, the pump from the piggyback receptacle and plug the if the needle goes to zero, the motor has a wire touching pump directly into the power source.
  • Page 7: Reassembly

    Maintenance Reassembly 13. Install bottom plate (12) and gasket (15). 14. To replace the power cord (22) on single phase 1. Thoroughly clean the seal (14) and bearing pockets pumps, first slip the stator lead wires through the in the volute. All sand and dirt must be removed. holes in the wire seal assembly.
  • Page 8: Troubleshooting

    Troubleshooting Hazardous voltage. Can shock, burn, or Hazardous impellers and unexpected starts Troubleshooting kill. Disconnect power before attempting any service or which can cause loss of fingers. Keep hands away from repair work on pump. pump suction inlet when working on or servicing pump. Symptom Possible Cause(s) Corrective Action...
  • Page 9: Repair Parts

    Repair Parts MES50 and MES100 Repair Parts Single Phase MOTOR LEAD CONNECTION DIAGRAMS FOR SINGLE PHASE PUMPS 115V GREEN 230V 6317 1210 Ref. Description Qty. Part Number Ref. Description Qty. Part Number Handle 000600005 Gasket 135620011 Housing, Motor 115V 000562322 O-Ring 000770031 Housing, Motor 230V...
  • Page 10 Repair Parts MES50 and MES100 Three Phase MOTOR LEAD CONNECTION DIAGRAMS FOR THREE PHASE PUMPS 6 V. 5 BK. 4 Y. 6 V. 5 BK. 4 Y. BR. 8 7 P. 7 P. GREEN GREEN 230V 460V 6352 1210 Ref. Description Qty.
  • Page 11: Warranty

    Warranty LIMITED WARRANTY Myers warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, ® that they will be free from defects in material and workmanship for the Warranty Period shown below . Warranty Warranty Period Product whichever occurs first: Jet pumps, small centrifugal pumps, submersible pumps and...
  • Page 12: Product Specifications

    Specifications Product Specifications Model MES50 MES100 Typical Application: Sewage, effluent, dewatering Capacities: up to 63 GPM (53 LPM) up to 88 GPM (74 LPM) Heads: up to 63 ft (19.2 m) up to 90 ft (27.4 m) Electrical: 115V, 1ø, 14.5 FLA, 60Hz; 208V, 1ø, 7.6 FLA, 60Hz; 208V, 1ø, 13.6 FLA, 60Hz;...
  • Page 13: Di Rectives De Sécurité Importantes

    Sécurité Table des matières Di rectives de sécurité importantes . . . . . . . . . . . . . . . . . .13 Installation .
  • Page 14: Installation

    Sécurité • Installation Toujours garder la zone de travail propre, débarrassée de Pression dangereuse - risque d’explosion et de tout débris et bien éclairée - enlever tous les outils et tout le blessures corporelles. Ne pas respecter les avertissements qui matériel dont on ne se sert pas.
  • Page 15 Installation Installation typique à une pompe seule phase Installation typique à une pompe tríphase...
  • Page 16: Utilisation

    Installation • Utilisation • Entretien Utilisation Suivez ces instructions d'installation : Fournissez une fosse aux dimensions adéquates (reportez-vous AVIS : Ne laissez pas la pompe fonctionner dans une fosse à sec. aux Caractéristiques) pour le réservoir d'eaux d'égout. Le Cela annulerait la garantie et pourrait endommager la pompe. temps de fonctionnement minimal de la pompe est de deux Une protection automatique contre les surcharges à...
  • Page 17: Vérification De La Terre

    Entretien Vé rification du fonctionnement Si le moteur est bien sec, l'aiguille de l'ohmmètre ne bougera pas lors de la vérification de la terre. La mesure indiquée est de 50 du moteur mégohms ou plus. Lors de la vérification de la terre, si l'aiguille Si l'appareil est actionné...
  • Page 18: Remontage

    Entretien Remontage 14. Pour remplacer le cordon d'alimentation (22) des pompes monophasées, faites d'abord glisser les fils de sortie du stator Nettoyez bien le joint (14) et les logements du roulement dans dans les orifices de l'ensemble de joint de fil. Recouvrez la volute.
  • Page 19: Dépannage

    Dépannage Tension dangereuse. Peut provoquer des chocs Impulseurs dangereux et démarrages inopinés électriques, des brûlures, voire la mort. Coupez l’alimentation pouvant provoquer la perte de doigts. Gardez les mains éloignées avant de tenter d’entretenir ou de réparer la pompe. de l’orifice d’aspiration de la pompe lorsque vous travaillez sur celle-ci ou lorsque vous la réparez.
  • Page 20: Pièces De Rechange

    Pièces de rechange Pièces de rechange Modèle monophasé Schémas de connexion des fils du moteur pour les pompes monophasées 115V VERT 230V 6317 1210 Numéro de Numéro de Ref. Description Qte. Ref. Description Qte. pièce pièce Poignée 000600005 Joint 135620011 Carter, moteur 115V 000562322 Joint torique...
  • Page 21 Pièces de rechange Modèle triphasé Schémas de connexion des fils du moteur pour les pompes triphasées 6 V. 5 BK. 4 Y. 6 V. 5 BK. 4 Y. BR. 8 7 P. 7 P. Vert Vert 230V 460V 6352 1210 Numéro de Numéro de Ref.
  • Page 22: Garantie

    Garantie Garantie limitée : Myers garantit à l’acheteur initial (« l’acheteur » ou « vous ») des produits figurant ci-dessous qu’ils seront ® exempts de tout défaut de matériel et de fabrication pour la période de garantie indiquée ci-dessous . Période de garantie Garantie Garantie...
  • Page 23: Caractéristiques Du Produit

    Caractéristiques Caractéristiques du produit Modèle MES50 MES100 Application typique Eaux d'égout, effluent, assèchement, capacité élevée Capacité : jusqu'à 63 GPM (53 LPM) jusqu'à 88 GPM (74 LPM) Hauteurs d'eau : jusqu'à 63 pi (19.2 m) jusqu'à 90 pi (27.4 m) 115V, 1ø, 14.5 FLA, 60Hz;...

This manual is also suitable for:

Myers mes50

Table of Contents