Refer to the configuration parameter table in the LED Light section of the Equipment Guide.:
Commands below are case sensitive.
1. Connect and power up the system, but do not start the control software.
2. Launch the terminal program and use the following commands to program the LED Light.
3. Navigate to the working folder, type:
cd flighthack followed by the Enter key
4. Enumerate the modules on the system, type:
vr_enum followed by the Enter key
5. The replacement LED Light serial number should appear in the list of enumerated devices, such
as LED000356 (LED will be present, but the number may be different)
6. Register the replacement LED Light, type:
vr_setid SN NodeID GroupID followed by the Enter key
where SN is the serial number of the replacement LED Light (case sensitive value as found in
the vr_enum output), and the NodeID and GroupID are from the
This step ensures that each LED Light has a unique Node ID on the this vehicle.
7. Type:
vr_enum followed by the Enter key
again to verify the replacement LED Light is registered with its Node ID.
8. Enter diagnostic mode of the replacement LED Light, type:
./vr_debug_putty.py NodeID followed by the Enter key
where [Node ID] is the Node ID of the replacement LED Light. This will open a new diagnostic
window.
9. To access the configuration menu in the diagnostic window, type:
c
You do not need to type the Enter key. In configuration mode you are now able to define the
LED Light's position on the vehicle (Application ID) and other operating parameters.
10. Using the values from the
Light to match those from the table. Minimally, the following settings should be entered or
confirmed:
1. Application ID (configuration parameter 21)
To change the values, follow these steps:
1. Type the Option Number followed by Enter, then type the Desired Value followed by
Enter.
11. Press the s key followed by Enter to save the configuration.
12. Press the x key followed by Enter to exit the configuration menu.
13. Press the x key again to exit diagnostic mode. You do not need to press Enter.
14. Close the diagnostic window.
15. Close the terminal window.
LED Light configuration table
LED Light configuration table
change the parameters on the LED