Troubleshooting and fault elimination

Troubleshooting

Error messages

Call up the keypad status messages to see the last error message.
Display ( ERROR ) Error
No error
NO ERROR
Faulty data
PR ERROR
exchange
Communicatio
COM BROK
n interrupted
RESET ERROR Communicatio
n with system
n with system
bus (CAN)
ASIC ERROR
interrupted
interrupted
SDO ERROR
Cause
-
Connection between keypad
and PC faulty
Serial data cable between
keypad and PC faulty or not
connected properly
Incorrect system bus wiring
(e.g. pole connection)
(e g pole connection)
Incorrect parameter setting
p
for interface (baud rate,
f i t f
(b d t
address, identifier)
EDBEPM-H315 DE/EN/FR 2.0
( ^ 44)
Remedy
-
Check connection
Check cable
Check Sub D plug connection
Replace serial data cable
Check wiring ( ^ 40 )
Check parameter setting ( ^ See
Check parameter setting ( ^ See
g
"HMI Designer - Getting Started"
g
Manual )