Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Show/Hide Bookmarks
EDBEPM-H315
!Ju7
L
Betriebsanleitung
Operating Instructions
Instructions de mise en service
F6
F7
F8
F1
F2
F3
V W X
Y Z –
+ / -
7
8
9
M N O
P Q R
S T U
4
5
6
D E F
G H I
J K L
1
2
3
·
A B C
shift
0
± space
Global Drive
EPM-H315
F9
F10
F4
F5
PgUp
Info
PgDN
Help
Clr
Esc
Enter

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EPM-H315 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lenze EPM-H315

  • Page 1 V W X Y Z – + / - Info PgDN M N O P Q R S T U Help D E F G H I J K L · A B C shift ± space Enter Global Drive EPM-H315...
  • Page 2 Show/Hide Bookmarks...
  • Page 3 Komplette Überarbeitung zur Serie ã 2001 Lenze GmbH & Co KG Ohne besondere schriftliche Genehmigung von Lenze GmbH & Co KG darf kein Teil dieser Dokumentation vervielfältigt oder Dritten zugänglich gemacht werden. Wir haben alle Angaben in dieser Dokumentation mit größter Sorgfalt zusammengestellt und auf Übereinstimmung mit der beschriebenen Hard- und Software geprüft.
  • Page 4: Table Of Contents

    Show/Hide Bookmarks Inhaltsverzeichnis 1 Vorwort und Allgemeines ........Über diese Betriebsanleitung .
  • Page 5: Vorwort Und Allgemeines

    Die vorliegende Betriebsanleitung dient dem sicheren und fehlerfreien Arbeiten an und mit der Bedieneinheit EPM-H315. • Alle Personen, die an und mit der Bedieneinheit EPM-H315 arbeiten, müssen bei ihren Arbeiten die Betriebsanleitung verfügbar haben und die für sie relevanten Angaben und Hinweise beachten.
  • Page 6: Piktogramme In Dieser Betriebsanleitung

    Wenn Sie ihn befolgen, erleichtern Sie sich die Handha- bung der Bedieneinheit. Lieferumfang Lieferumfang Wichtig • 1 Bedieneinheit EPM-H315 Überprüfen Sie nach Erhalt der Lieferung sofort, ob der • Lieferumfang mit den Warenbegleitpapieren überein- 1 Betriebsanleitung stimmt. Für nachträglich reklamierte Mängel über- •...
  • Page 7: Technische Daten

    Show/Hide Bookmarks Technische Daten Technische Daten Allgemeine Daten und Einsatzbedingungen Bereich Werte Isolationsspannung zur Bezugserde/PE: 50 V AC Isolationsfestigkeit IP65 (Front) Schutzart im Betrieb: 0 ... +50 °C Zulässige Temperaturbereiche Transport: -20 ... +60 °C Lagerung: -20 ... +60 °C <85 %, keine Betauung Feuchtebeanspruchung Gewicht...
  • Page 8: Elektrische Daten

    Show/Hide Bookmarks Technische Daten Elektrische Daten Bereich Werte Display Display Darstellungsformat Text Sichtbare Größe 70.4 × 20.8 mm Zeilen × Zeichen 4 × 20 Zeichengröße 2.95 × 4.75 mm Zeichengröße im Textmodus 5 × 7 Pixel Fonts ASCII, Katakana Kontrasteinstellung Trimmpotentiometer Hintergrundbeleuchtung Elektrischer An-...
  • Page 9: Eigenschaften Der Bedieneinheit

    Show/Hide Bookmarks Technische Daten 2.2.1 Eigenschaften der Bedieneinheit Seiten [Anzahl] 1024 Seiten-Hilfe [Anzahl] 1024 Hilfemeldungen [Anzahl] 1024 Informationsmeldungen [insgesamt/gleichzeitig aktiv] 1024/128 Paßwort [Ebenen] Bit-Paßwort [Bit] Dynamische Texte (mit Bitgruppen-Struktur, Einzelbit- [Anzahl] 1024 Struktur oder Wert-Struktur) Online Sprachen [Anzahl] Programmierbare Tasten [Anzahl] Variablen Variablen...
  • Page 10: Abmessungen

    Show/Hide Bookmarks Technische Daten Abmessungen PgUp V W X Y Z – + / - Info P Q R S T U PgDN M N O Help D E F G H I J K L · A B C shift ±...
  • Page 11: Installation

    Show/Hide Bookmarks Installation Installation Mechanische Installation 3.1.1 Tastatur beschriften Die Bedieneinheit kann mit auswechselbaren Schildern beschriftet werden. • Die Schilder sind nur bei ausgebauter Bedieneinheit zugänglich. • Beschriften Sie die Schilder, bevor Sie die Bedieneinheit in die Einbautafel montieren. 1. Schild , oder zum Beschriften aus dem Schlitz ziehen.
  • Page 12: Bedieneinheit Einbauen

    Show/Hide Bookmarks Installation 3.1.2 Bedieneinheit einbauen Die Maße für den Einbauausschnitt entnehmen Sie den technischen Daten. ( ^ 10) 1. Bedieneinheit mit Dichtung in den Einbauausschnitt schieben. H315_006 2. Befestigungsschellen in die Öffnungs- schlitze der Bedieneinheit schieben. H315_010 3. Schrauben gegen die Einbautafel dre- hen und festziehen.
  • Page 13: Elektrische Installation

    Show/Hide Bookmarks Installation Elektrische Installation 3.2.1 Belegung der Anschlußklemmen Stop! Um eine Beschädigung der Bedieneinheit und eines angeschlossenen PC zu vermeiden, müssen Sie • die Bedieneinheit immer im spannungslosen Zustand verdrahten, • den PE-Leiter 0 ausschließlich so verbinden, wie es in der Abbildung dargestellt ist. LCD adj.
  • Page 14: Verdrahtung Des Systembus (Can)

    Show/Hide Bookmarks Installation 3.2.2 Verdrahtung des Systembus (CAN) Prinzipieller Aufbau (H315) CAN- Shield CAN+ N.C. CG LO HI CG LO HI CG LO HI CG LO H315_004 Busteilnehmer 1 Busteilnehmer 2 Busteilnehmer n • Verbinden Sie nur Klemmen gleichen Signaltyps miteinander. •...
  • Page 15: Inbetriebnahme

    Show/Hide Bookmarks Inbetriebnahme Inbetriebnahme Erstes Einschalten Für die Inbetriebnahme ist eine vollständige Verdrahtung des Systembus notwendig. Stop! Überprüfen Sie vor dem Einschalten der Versorgungsspannung • die gesamte Verdrahtung auf Vollständigkeit und Kurzschluß, • ob das Bussystem beim physikalisch ersten und letzten Busteilnehmer abgeschlossen ist. EDBEPM-H315 DE/EN/FR 2.0...
  • Page 16: Projekt In Die Bedieneinheit Übertragen

    Show/Hide Bookmarks Inbetriebnahme Projekt in die Bedieneinheit übertragen 4.2.1 Bedieneinheit und PC verbinden Stop! Die Verbindung zwischen PC und Bedieneinheit nur bei ausgeschalteten Geräten herstellen! LCD adj. INPUT VOLTAGE: 18-32VDC 15W FUSE 800mA N.C. 24VDC ASP8 1 2 3 4 5 H315_005 Schritt Programmieradapter EPZ-H111...
  • Page 17: Projekt Downloaden

    Show/Hide Bookmarks Inbetriebnahme 4.2.2 Projekt downloaden Im HMI Designer können Sie auswählen, ob mit dem Laden des Projekts gleichzeitig die Firmware ak- tualisiert werden soll. • Aktualisieren Sie die Firmware immer: – Beim ersten Download eines Projekts in die Bedieneinheit. –...
  • Page 18: Verbindung Zum Pc Entfernen

    Sie möchten ... Drücken Sie die Tasten ... Beispiel den Status der Bedieneinheit abfragen. Serial: NET Serial: NET Serial: NET shift Driver: Can Lenze S Driver: Can Lenze S Driver: Can Lenze S Ver. Ver. Ver. : 1.03 : 1.03 : 1.03...
  • Page 19: Bedienung

    Show/Hide Bookmarks Bedienung Bedienung Tastenfunktionen Tasten Funktion Erläuterung Funktion von F1 ... F5 ausführen <F1> ... <F5> (Tasten programmierbar) Funktion von F6 ... F10 ausführen <F6> ... <F10> shift (Tasten programmierbar) <0> ... <9> A B C + / - Alphanumerische Tasten für die Dateneingabe <ABC>...
  • Page 20: Daten Eingeben

    Show/Hide Bookmarks Bedienung Daten eingeben Das Eingeben oder Ändern von Daten ist Schritt für Schritt dargestellt und wird an einem Beispiel erläu- tert. Sie möchten ... Drücken Sie die Tasten ... Beispiel ein Menü auswählen. bzw. shift eine Seite anwählen. PgUp PgDN oder...
  • Page 21 Show/Hide Bookmarks Bedienung Sie möchten ... Drücken Sie die Tasten ... Beispiel eine einzelne Ziffer ändern. 1. Wechseln Sie in die Parameter-Ebene (siehe Schritt D.). 2. Wählen Sie die gewünschte Ziffer. Feld 1 Feld 1 Feld 1 oder Feld 2 Feld 2 Feld 2 -1 34...
  • Page 22: Informationsmeldung Aufrufen

    Show/Hide Bookmarks Bedienung Informationsmeldung aufrufen • Informationsmeldungen – sind Texte, die aufgrund eines Ereignisses angezeigt werden (z. B., wenn ein Istwert eine Grenze übersteigt), – können Sie nur aufrufen, solange das auslösende Ereignis vorhanden ist, – müssen im Projektierungstool “HMI Designer” programmiert worden sein, –...
  • Page 23: Fehlersuche Und Störungsbeseitigung

    Show/Hide Bookmarks Fehlersuche und Störungsbeseitigung Fehlersuche und Störungsbeseitigung Störungsmeldungen Rufen Sie die Statusmeldungen der Bedieneinheit auf, um die zuletzt aufgetretene Störungsmeldung anzuzeigen. ( ^ 18) Display ( ERROR ) Störung Ursache Abhilfe Keine Störung NO ERROR • Fehlerhafter Verbindung zwischen Bedien- Anschlüsse auf festen Sitz prüfen PR ERROR Datenaus-...
  • Page 24: Wartung

    – Wenn Sie ein anderes Reinigungsmittel verwenden müssen, um Verunreinigungen zu beseitigen, beachten Sie die Angaben in der Tabelle im Kap. 8.1. ( ^ 25) Serviceadressen Die Adressen Ihrer Lenze-Ansprechpartner in aller Welt finden Sie auf der hinteren Umschlagseite jeder Lenze-Druckschrift. EDBEPM-H315 DE/EN/FR 2.0...
  • Page 25: Anhang

    Chemikalien. Stop! Die Bedien-Oberfläche ist wenig beständig gegen saure Nahrungsmittel (z. B. Tomatensaft, Zitronensaft). Verschmutzungen deshalb gleich entfernen, sonst kann die Oberfläche beschädigt werden. Bedieneinheit EPM-H310 EPM-H410 EPM-H510 Substanz EPM-H315 EPM-H520 Aceton — Benzin Benzol Benzylalkohol — — Dieselöl ≥...
  • Page 26: Stichwortverzeichnis

    Show/Hide Bookmarks Anhang Stichwortverzeichnis Daten, eingeben, 20 Abmessungen Bedieneinheit, 10 DC-Spannungsversorgung, 8 Einbauausschnitt, 10 Display, 8 Anschluß, elektrischer, 8 Kontrast einstellen, 18 Anschlußklemmen, Belegung, 13 Antriebsregler, 5 Eigenschaften, 9 Einsatzbedingungen, 7 Feuchtebeanspruchung, 7 Isolationsfestigkeit, 7 Baudrate, Systembus (CAN), 8 Schutzart, 7 Bedieneinheit zulässige Temperaturbereiche, 7 beschriften, 11...
  • Page 27 Show/Hide Bookmarks Anhang Schutzart, 7 Informationsmeldung, 22 Serviceadressen, 24 Installation, 11 Sicherheitshinweise, Gestaltung Anschlußklemmen, Belegung, 13 Sonstige Hinweise, 6 elektrische, 13 Warnung vor Sachschäden, 6 mechanische, 11 Speicher, 8 Systembus (CAN), 14 Statusmeldungen, 18 Isolationsfestigkeit, 7 Störungsmeldungen, 23 Systembus (CAN) Baudrate, 8 Kommunikationsmedium, 8 Kontrast, einstellen, 18...
  • Page 28 Show/Hide Bookmarks Anhang EDBEPM-H315 DE/EN/FR 2.0...
  • Page 29 Show/Hide Bookmarks About these Instructions This documentation only applies to the keypad EPM-H315 as of version: EPM-H315 Type Hardware version Software version Version Id-No. Changes – 06/2000 TD23 00415798 First edition for field test 08/2001 TD02 00418422 Complete revision for series production ã...
  • Page 30 Show/Hide Bookmarks Contents 1 Preface and general information ........About these Operating Instructions .
  • Page 31: Preface And General Information

    Preface and general information Preface and general information The EPM-H315 keypad can be used to access codes of Lenze controllers, 9300 Servo PLC and Drive PLC and to facilitate the use of these devices. The HMI Designer is a powerful development environment for creating projects containing the configuration of the keypad.
  • Page 32: Pictograms Used In These Operating Instructions

    1 EPM-H315 keypad After receipt of the delivery, check immediately • whether the items delivered match the accompanying 1 Operating Instructions papers. Lenze does not accept any liability for • 4 Fixing clamps deficiencies claimed subsequently. • 4 M4 x 35 mm screws Report •...
  • Page 33: Technical Data

    Show/Hide Bookmarks Technical data Technical data General data and application conditions Field Values Insulation resistance to PE: 50 V AC Insulation resistance IP65 (front) Type of protection during operation: 0 ... +50 °C Permissible temperature range during transport: -20 ... +60 °C during storage -20 ...
  • Page 34: Electrical Data

    Show/Hide Bookmarks Technical data Electrical data Field Values Display Display Type Display format Text Visible size 70.4 x 20.8 mm Lines Characters 4 x 20 Character size 2.95 x 4.75 mm Character size in text mode 5 x 7 pixel Fonts ASCII, Katakana Contrast setting...
  • Page 35: Features Of The Keypad

    Show/Hide Bookmarks Technical data 2.2.1 Features of the keypad Pages [Number] 1024 Help [Number] 1024 Help messages [Number] 1024 Information messages [Total/active at the same time] 1024/128 Password [Levels] Bit password [bit] Dynamic texts (with bit group structure, single bit [Number] 1024 structure or value structure)
  • Page 36: Dimensions

    Show/Hide Bookmarks Technical data Dimensions PgUp V W X Y Z – + / - Info P Q R S T U PgDN M N O Help D E F G H I J K L · A B C shift ±...
  • Page 37: Installation

    Show/Hide Bookmarks Installation Installation Mechanical installation 3.1.1 Keypad labelling Different labels can be attached to the keypad. • The labels are only accessible when the keypad is not built in. • Ensure to have the labels ready for use before the keypad is mounted into the mounting cut-out.
  • Page 38: Keypad Mounting

    Show/Hide Bookmarks Installation 3.1.2 Keypad mounting The dimensions for the mounting cut-out can be found in from the Technical Data ( ^ 36) 1. Keypad and the seal into the cut-out. H315_006 2. Insert the fixing clamps into the slots on the keypad.
  • Page 39: Electrical Installation

    Show/Hide Bookmarks Installation Electrical installation 3.2.1 Assignment of the connection terminals Stop! Damage of the keypad and the connected PC can be avoided by • wiring the keypad when the voltage has been disconnected, • connecting the PE conductor 0 as shown in the diagram. LCD adj.
  • Page 40: System Bus Wiring (Can)

    Show/Hide Bookmarks Installation 3.2.2 System bus wiring (CAN) Schmatic diagram (H315) CAN- Shield CAN+ N.C. CG LO HI CG LO HI CG LO HI CG LO H315_004 Bus device 1 Bus device 2 Bus device n • Only connect terminals of the same signal type. •...
  • Page 41: Commissioning

    Show/Hide Bookmarks Commissioning Commissioning First switch on For commissioning, the system bus must be completely wired. Stop! Check the supply voltage before switching on the unit. • Check the wiring for completeness and short circuits, • Check whether the bus system is terminated physically at the first and last device. EDBEPM-H315 DE/EN/FR 2.0...
  • Page 42: Transferring Of The Project To The Keypad

    Show/Hide Bookmarks Commissioning Transferring of the project to the keypad 4.2.1 Connection of keypad and PC Stop! Only connect PC and keypad when the units are switched off! LCD adj. INPUT VOLTAGE: 18-32VDC 15W FUSE 800mA N.C. 24VDC ASP8 1 2 3 4 5 H315_005 Step EPZ-H111 programming adapter...
  • Page 43: Project Download

    Show/Hide Bookmarks Commissioning 4.2.2 Project download The HMI designer can be used to load the project and update the firmware at the same time. • Always update the firmware in the following situations: – When downloading a project into the keypad for the first time. –...
  • Page 44: Disconnection From The Pc

    If you want to ... Press keys ... Example to query the status of the keypad. Serial: NET Serial: NET Serial: NET shift Driver: Can Lenze S Driver: Can Lenze S Driver: Can Lenze S Ver. Ver. Ver. : 1.03 : 1.03 : 1.03...
  • Page 45: Operation

    Show/Hide Bookmarks Operation Operation Key functions Keys Function Explanation Keys F1 ... F5 <F1> ... <F5> (keys programmable) Keys F6 ... F10 <F6> ... <F10> shift (keys programmable) <0> ... <9> A B C + / - Alpha-numerical keys for entering data <ABC>...
  • Page 46: Data Input

    Show/Hide Bookmarks Operation Data input Data input and modification are described step-by-step using examples. If you want to ... Press keys ... Example select a menu. shift go to a page. PgUp PgDN set the cursor to the previous or next field. Field 1 Field 1 Field 2...
  • Page 47 Show/Hide Bookmarks Operation If you want to ... Press keys ... Example a figure. 1. Change to the parameter level (see step D.). 2. Select the digit wanted . Field 1 Field 1 Field 1 Field 2 Field 2 Field 2 -1 34 -1 34 -1 34...
  • Page 48: Calling Up Information Messages

    Show/Hide Bookmarks Operation Calling up information messages • Information messages – are texts which appear because of a certain event (e.g. if an actual value exceeds a limit), – can only be called as long as the triggering event is active, –...
  • Page 49: Troubleshooting

    Show/Hide Bookmarks Troubleshooting and fault elimination Troubleshooting Error messages Call up the keypad status messages to see the last error message. ( ^ 44) Display ( ERROR ) Error Cause Remedy No error NO ERROR • Faulty data Connection between keypad Check connection PR ERROR •...
  • Page 50: Maintenance

    – If you use any other cleaning agents, please see the table in chapter 8.1. ( ^ 51) Service addresses The addresses of all Lenze representatives world-wide are listed on the last page of every Lenze document. EDBEPM-H315 DE/EN/FR 2.0...
  • Page 51: Appendix

    The surfaces do not resist acidic food (e.g. tomato juice, lemon juice) very well. We therefore recommend to clean off these marks immediately, otherwise the surface can be damaged. Keypad EPM-H310 EPM-H410 EPM-H510 Substance EPM-H315 EPM-H520 Acetone — Benzene Benzole Benzyl alcohol —...
  • Page 52: Table Of Keywords

    Show/Hide Bookmarks Appendix Table of keywords First switch on, 41 Application conditions, 33 Humidity, 33 Insulation resistance, 33 Permissible temperature range, 33 Type of protection, 33 Help, 48 Human Machine Interface, 31 Humidity, 33 Baud rate, System bus (CAN), 34 Information message, 48 Installation, 37 Chemical resistance, 51...
  • Page 53 Show/Hide Bookmarks Appendix Safety Instructions, Layout Maintenance, 50 Other notes, 32 Warning of damage to materal, 32 Memory, 34 Scope of supply, 32 Service addresses, 50 Switch on, first, 41 System bus (CAN) Output, 44 Baud rate, 34 Communication medium, 34 Wiring, 40 Parameters, 35 Technical data...
  • Page 54 Show/Hide Bookmarks Appendix EDBEPM-H315 DE/EN/FR 2.0...
  • Page 55 Show/Hide Bookmarks Information générale Le présent document s’applique à l’unité de commande EPM-H315 à partir de la version : EPM-H315 Type Version du matériel Version du logiciel Edition N° d’ident. Modifications – 06/2000 TD23 00415798 Première édition pour essais sur le terrain...
  • Page 56 Show/Hide Bookmarks Table des matières 1 Avant-propos et généralités ........Comment utiliser ces instructions de mise en service .
  • Page 57: Avant-Propos Et Généralités

    Avant-propos Avant-propos et généralités L’unité de commande EPM-H315 permet d’accéder aux codes des variateurs de vitesse Lenze, du Servo PLC 9300 et du Drive PLC et de commander ces appareils de façon conviviale. L’outil de conception performant HMI Designer vous permet d’établir des projets comprenant la configuration de l’unité...
  • Page 58: Pictogrammes Utilisés Dans Le Présent Fascicule

    Equipement livré Equipement livré IMPORTANT • 1 unité de commande EPM-H315 Vérifier à réception que l’équipement livré est • conforme au bon de livraison. Aucune réclamation ne 1 documentation ”Instructions de mise en service”...
  • Page 59: Spécifications Techniques

    Show/Hide Bookmarks Spécifications techniques Spécifications techniques Caractéristiques générales et conditions ambiantes Domaine Données Tension d’isolement bus - point de terre/PE : 50 V CA Résistance à l’isolement IP65 (face avant) Protection Fonctionnement 0 ... +50 °C Plages de température admissibles Transport -20 ...
  • Page 60: Caractéristiques Électriques

    Show/Hide Bookmarks Spécifications techniques Caractéristiques électriques Domaine Données Affichage Affichage Type Format de présentation Texte Taille d’affichage 70,4 x 20,8 mm Lignes x caractères 4 x 20 Taille de caractères 2,95 x 4,75 mm Taille caractère en mode texte 5 x 7 pixel Fontes ASCII, Katakana Réglage des contrastes...
  • Page 61: Caractéristiques De L'unité De Commande

    Show/Hide Bookmarks Spécifications techniques 2.2.1 Caractéristiques de l’unité de commande Pages [nombre] 1024 Aide-pages [nombre] 1024 Messages d’aide [nombre] 1024 Messages d’information [total/activés simultanément] 1024/128 Mot de passe [niveaux] Mot de passe en bits [bits] Textes dynamiques (avec structure groupe bits, [nombre] 1024 structure bit individuel ou structure valeur)
  • Page 62: Encombrements

    Show/Hide Bookmarks Spécifications techniques Encombrements PgUp V W X Y Z – + / - Info P Q R S T U PgDN M N O Help D E F G H I J K L · A B C shift ±...
  • Page 63: Installation

    Show/Hide Bookmarks Installation Installation Installation mécanique 3.1.1 Etiquetage des touches L’unité de commande permet le changement d’étiquettes. • Les étiquettes ne sont accessibles que si l’unité de commande est démontée. • Ecrire les étiquettes avant de monter l’unité de commande dans l’encoche de montage. 1.
  • Page 64: Montage De L'unité De Commande

    Show/Hide Bookmarks Installation 3.1.2 Montage de l’unité de commande Pour les cotes de l’encoche de montage, se reporter au chapitre Spécifications techniques. ( ^ 62) 1. Glisser l’unité de commande et le joint dans l’encoche de montage. H315_006 2. Placer les colliers de fixation dans les ouvertures prévues à...
  • Page 65: Installation Électrique

    Show/Hide Bookmarks Installation Installation électrique 3.2.1 Affectation des bornes Stop ! Afin d’éviter tout endommagement de l’unité de commande et du PC connecté, • ne raccorder l’unité de commande qu’en absence de tension, • ne raccorder le câble de mise à la terre PE 0 uniquement comme indiqué sur l’illustration. LCD adj.
  • Page 66: Câblage Du Bus Système (Can)

    Show/Hide Bookmarks Installation 3.2.2 Câblage du bus système (CAN) Principe de câblage (H315) CAN- Shield CAN+ N.C. CG LO HI CG LO HI CG LO HI CG LO H315_004 Abonné au bus 1 Abonné au bus 2 Abonné au bus n •...
  • Page 67: Mise En Service

    Show/Hide Bookmarks Mise en service Mise en service Première mise en service Pour la mise en service, il est impératif que le bus système soit correctement raccordé. Stop ! Avant la mise sous tension, vérifier • le câblage dans son intégralité pour éviter un court-circuit, •...
  • Page 68: Transférer Le Projet Dans L'unité De Commande

    Show/Hide Bookmarks Mise en service Transférer le projet dans l’unité de commande 4.2.1 Relier l’unité de commande et le PC Stop ! Ne relier le PC et l’unité de commande qu’en absence de tension ! LCD adj. INPUT VOLTAGE: 18-32VDC 15W FUSE 800mA N.C.
  • Page 69: Télécharger Un Projet

    Show/Hide Bookmarks Mise en service 4.2.2 Télécharger un projet L’outil de conception HMI Designer vous permet de déterminer si, simultanément au chargement du projet, le micrologiciel doit être actualisé. • Il faut toujours procéder à l’actualisation du logiciel – lors du premier téléchargement d’un projet dans l’unité de commande, et –...
  • Page 70: Déconnexion Du Pc

    Pour ... appuyer sur les touches : Exemple connaître l’état de l’unité de commande Serial: NET Serial: NET Serial: NET shift Driver: Can Lenze S Driver: Can Lenze S Driver: Can Lenze S Ver. Ver. Ver. : 1.03 : 1.03 : 1.03...
  • Page 71: Commande

    Show/Hide Bookmarks Commande Commande Fonction des touches Touches Fonction Explication Exécuter la fonction de F1 ... F5 <F1> ... <F5> (touches programmables). Exécuter la fonction de F6 ... F10 <F6> ... <F10> shift (touches programmables). <0> ... <9> A B C + / - Touches alphanumériques pour l’entrée de données <ABC>...
  • Page 72: Entrer Des Données

    Show/Hide Bookmarks Commande Entrer des données L’ordre chronologique pour l’entrée et la modification des données est décrit à l’aide d’un exemple. Pour ... appuyer sur les touches : Exemple sélectionner un menu shift sélectionner une page PgUp PgDN placer le curseur sur le champ suivant ou le Champ 1 Champ 1 champ précédent...
  • Page 73 Show/Hide Bookmarks Commande Pour ... appuyer sur les touches : Exemple modifier un chiffre individuel 1. Passer au niveau paramètres (voir D.). 2. Sélectionner le chiffre souhaité. Champ 1 Champ 1 Champ 1 Champ 2 Champ 2 Champ 2 -1 34 -1 34 -1 34 Champ 3...
  • Page 74: Appeler Un Message D'information

    Show/Hide Bookmarks Commande Appeler un message d’information • Les messages d’information – sont des textes affichables suite à un événement (exemple : la valeur réelle a dépassé une limite) ; – ne peuvent être appelés que pendant que l’événement déclenchant le message est actif ; –...
  • Page 75: Détection Et Élimination Des Défauts

    Show/Hide Bookmarks Détection et élimination des défauts Détection et élimination des défauts Messages défauts Appeler les messages d’état de l’unité de commande pour afficher le dernier défaut apparu. ( ^ 70) Affichage Défaut Origine Remède ( ERROR ) Sans défaut NO ERROR •...
  • Page 76: Maintenance

    8.1. ( ^ 77) Adresses S.A.V. Vous trouverez les adresses du S.A.V. ou des agences LENZE dans le monde entier sur la dernière page de la couverture de chaque documentation Lenze. EDBEPM-H315 DE/EN/FR 2.0...
  • Page 77: Annexe

    En cas de projection de produits acides sur l’interface opérateur, il faut la nettoyer immédiatement sous risque de l’endommager. Unité de commande EPM-H310 EPM-H410 EPM-H510 Substance EPM-H315 EPM-H520 Acétone — ≥ 5 % Acide acétique ≥ 10 % Acide chlorhydrique ≥...
  • Page 78: Index

    Show/Hide Bookmarks Annexe Index Encombrements Adresses S.A.V., 76 Encoche de montage, 62 Affichage, 60 Unité de commande, 62 Réglage des contrastes, 70 Equipement livré, 58 Aide, 74 Alimentation CC, 60 Fonction des touches, 71 Bornes de raccordement, Affectation, 65 Bus système (CAN) Human Machine Interface Câblage, 66 (Interface homme-machine), 57...
  • Page 79 Show/Hide Bookmarks Annexe Spécifications techniques Affectation de la prise, 61 Affichage, 60 Alimentation CC, 60 Déconnexion de l’unité de commande, 70 Bus système (CAN), 60 Relier l’unité de commande et le PC, 68 Caractéristiques générales/conditions ambiantes, 59 Mémoire, 60 Poids, 59 Plages de température admissibles, 59 Puissance absorbée, 60 Raccordement électrique, 60...
  • Page 80 Show/Hide Bookmarks Annexe EDBEPM-H315 DE/EN/FR 2.0...