Epever XTRA N Series User Manual page 40

Mppt solar charge controller
Table of Contents

Advertisement

RS485 interface
LCD backlight time
①When lithium battery is used, the system voltage can't be identified automatically.
②At minimum operating environment temperature
③At 25℃ environment temperature
④When lithium battery is used, the temperature compensate coefficient must be 0,and can't be changed.
Environmental Parameters
Working environment temperature
(100% input and output)
Storage temperature range
Relative humidity
Enclosure
Pollution degree
The controller can full load working in the working environment temperature, When the internal temperature reach to 81℃, the
reducing charging power mode is turned on. Refer to P34.
★3-protection against solid objects: protected against solids objects over 2.5mm.
2-protection against liquids: protected against direct sprays up to 15°from the vertical.
Mechanical Parameters
XTRA1206N
Item
XTRA1210N
Dimension
175×143×48mm
Mounting dimension
120×134mm
Mounting hole size
Terminal
12AWG(4mm
Recommended cable
12AWG(4mm
Weight
Certification
Safety
EMC(Emission immunity)
Default:60S,Range:0~999S(0S:the backlight is ON all the time)
XTRA2206N
XTRA2210N
217×158×56.5mm
160×149mm
2
)
6AWG(16mm
2
)
10AWG(6mm
0.57kg
0.96kg
5VDC/200mA(RJ45)
-25℃~+50℃(LCD)
-30℃~+50℃(No LCD)
XTRA3210N
230×165×63mm
255×185×67.8mm
173×156mm
Φ5mm
2
2
)
6AWG(16mm
)
2
2
)
8AWG(10mm
)
1.31kg
EN/IEC62109-1
EN61000-6-3/EN61000-6-1
37
-20℃~+70℃
≤95%, N.C.
IP32
PD2
XTRA3215N
XTRA3415N
XTRA4210N
XTRA4215N
255×187×75.7mm
200×176mm
200×178mm
2
6AWG(16mm
)
6AWG(16mm
2
6AWG(16mm
)
8AWG(16mm
1.70kg
2.07kg
XTRA4415N
255×189×83.2mm
200×180mm
2
2
)
6AWG(16mm
)
2
2
)
6AWG(16mm
)
2.47kg

Hide quick links: