Summary of Contents for WALTHER PILOT PILOT WA 900
Page 1
WALTHER PILOT Operating Manual Automatic Spray Guns PILOT WA 900 / PILOT WA 905 Models AUSG. 03/13 DISTRIBUTED BY COATING EQUIPMENT TECHNOLOGY, INC PHONE: 586-210-0555 WEB: www.cetinc.com...
Page 2
Adapter Low-Profile PILOT WA 900 With internal control Adapter Standard PILOT WA 905 With external control...
Model identification Fax: +49(0)202 / 787 - 2217 Intended Use www.walther-pilot.de • e-mail: info@walther-pilot.de Improper Use Types Automatic Spray Guns PILOT WA 900-Serie Technical Description (Standard with internal control) WA 900 V 21 900 Standard with external control) WA 905...
Page 4
Spare Parts List: Spare Parts List: WA 900 WA 905 WA 920 HVLP WA 925 HVLP (with internal control) (with external control) (Internal Control) (External Control) V 21 900 V 21 905 V 21 920 V 21 925 Description Pcs. Part Number Pcs.
Page 5
Air Cap V 10 700 36 xxx* V 10 700 36 xxx* WALTHER PILOT for automatic spray guns PILOT WA 900 - prepared containing all parts subject to WA 945 HVLPPlus repair kits. Material Nozzle V 10 700 40 xx3*...
Page 6
7 / 9 7 / 9 8 / 10 8 / 10 8 / 10 8 / 10 Spare parts list for adapter plate aluminum, nickel-plated Spare parts list for adapter plate stainless steel Adapter plate Adapter plate Adapter Plate Adapter Plate Material connection back Material connection back...
Intended Use Improper Use The automatic spray guns PILOT WA 900, WA 905, WA 920, WA 925, WA 940 and This spray gun shall not be used for purposes other than set forth in the above WA 945 are for the processing of sprayable media, such as: Chapter 1.2 Normal Use.
You can set the spray pattern shape in the PILOT WA 900 / WA-920 and General Applicable Safety Precautions WA HVLP 940-HVLPPLUS with the control screws (Items 33 and 34) on the gun.
configuration, the gun can be used only Operational Handling with a standard, non-recirculation, system. Safety Warnings The locking pin (item 37) must be removed if you have decided to use your gun with a Please pay special attention to the following safety warnings prior to taking the recirculating system.
Spray Pattern Adjustments Correcting Spray Pattern Imperfections The following table shows the settings you can alter to affect spray pattern You can change the spray pattern on the PILOT WA 900-series through the inconsistencies. Desired Spray Pattern following settings:...
The internal moving parts should be greased at least once weekly. The springs will then be constantly provided with a thin layer of grease. Use WALTHER PILOT gun grease and a brush to do so.
Never re-use a used Needle Seal Packing (Part. 9) as otherwise the functional sealing reliability of the spray gun is not guaranteed. The material supply of the series PILOT WA 900 can be manually released so that Replacement of Nozzles, Needles, Springs, and Seals is it not necessary to operate the complete spraying system.
Air Cap Inlet Pressure to Air consumption the gun Disposal of any such substances must be in accordance with all applicable local and national regulations, directives and laws. PILOT WA 900 1038 4,0 bar L/min. PILOT WA 920 HVLP 1061 3,5 bar L/min.