Installation instructions
1.
Mounting the system components
Observe the following during mounting:
• Only use shielded cables.
• The standard precautions for C-MOS technology must be taken when
handling PCBs This also applies for soldering work. Wear a grounding
armband when working on the control panel
Mounting the control unit
• Mount the control unit on the wall. When selecting the position, be aware that the SPE
blocking element has a fixed molded cable of 6 m length, which cannot be
extended.
Mounting the SPE blocking element
•
Mount the SPE blocking element using the appropriate kit in line with the mounting
instructions enclosed.
Ensure the door cannot bang shut. Otherwise the SPE blocking element bolt
could be damaged during commissioning by a door banging shut.
2.
Mounting of magnet contact and bolt contact
Mount the magnet contact or bolt contact according to the appropriate manufacturer's
instructions. The control unit serves as the distributor for the contacts .