Technical data

SE 60 LSNi control unit
Operating voltage
Total current consumption including blocking
element at an input voltage of 9.6 V
- Standby LSN part
- Standby additional
supply
- Bolts are engaged
- Bolts blocked
Total current consumption including blocking
element at an input voltage of 28 V
- Standby LSN part
- Standby additional
supply
- Bolts are engaged
- Bolts blocked
Environmental
Conditions
- Environmental class
- Protection category
- Operating temperature -5 °C to +45 °C
- Storage temperature -40 °C to +85 °C
Housing
- Material
- Color
Dimensions
(H x W x D)
Weight
VdS approval
(class C) for whole
system
Laws/Standards/Guidelines
The system fulfills all the requirements
resulting from the relevant laws, standards
and guidelines, in particular
- EN 61000-6-3
- EN 50130-4
- DIN VDE 0833, Part 1 and 3
- VdS 2110
- VdS 2227
- VdS 2119
- VdS 2311
- VdS 2203
- VdS 2252
9.6 V to 30 V
3.53 mA
41 mA
110 mA for 200 ms
470 mA for 200 ms
3.53 mA
30 mA
65 mA for 200 ms
200 mA for 200 ms
2
IP 30
ABS
RAL 9002
160 x 135 x 35 mm
0.25 kg
G 106062, C
Blocking element
Maximum distance
between bolt and locking
plate
Bolt break force
Cable to control unit
Environmental Conditions
- Environmental class
- Protection category
- Operating temperature
- Storage temperature
Housing
- Material
- Color
Weight
- Surface mounted
models
- Recessed mounted
models
Dimensions (H x W x D)
Note on blocking element: SE 60 LSNi
without bolt contact. If all the bolts of all SE
60 LSNi in a detection area are activated
at the same time, the values for "Bolt
activated" must be added together when
calculating the current. Due to the time
shift caused by the LSN, up to four
SE 60 LSNi can be activated within 200 ms.
12
4 mm
Approx. 1 kN
Max. 6 m, 6-pin,
shielded,
permanently sealed
3
IP 44
-25 °C to +55 °C
-40 °C to +85 °C
ABS
RAL 9002
0.45 kg
0.40 kg
28 x 118 x 16 mm