Setting the impact speed
EN
corresponding to the length
of the socket used
(EYFLA9, EYFMA2)
To set the stable impact speed based on the
length of the socket used, do as follows:
1. Set the tool to the configuration mode.
(See page 18.)
2. Press button D three times.
• The current set value is displayed, and
the main unit panel starts flashing.
Display: h0 flashing.
Battery capacity indicator: The upper
and lower bars flash.
[Fig.32]
3. Press
and
change the value.
Display
h0
h1
h2
4. Press the OK button to accept the new
setting.
Setting use interval
Use interval is set to prevent the screwdriver
from continuing its operation when the
tool is automatically stopped due to the
implementation of the torque correction
feature. This setting is valid even when the
switch is off.
1. Set the tool to the configuration mode.
(See page 18.)
[EYFLA4, EYFLA5, EYFLA6, EYFMA1]
2. Press button B.
• The main unit panel starts flashing.
Display: 0 flashing intermittently.
Battery capacity indicator: The middle
bar flashes intermittently.
[Fig.33]
buttons as required to
Impact Speed Standard
Standard socket
(high speed)
Up to 150 mm socket
(medium speed)
Up to 250 mm socket
(low speed)
3. Press
and
set the time.
Operation
4. Press OK to confirm the settings.
• The control panel stops flashing and lights
up to display the torque clutch settings.
NOTE:
Check the new value after you change the
settings.
[EYFLA7, EYFLA8, EYFLA9, EYFMA2]
2. Press button D twice.
• The current set value is displayed, and
the main unit panel starts flashing.
Display: U flashing.
Battery capacity indicator: The upper and
lower bars flash.
[Fig.33]
3. Press
and
the time.
Operation
4. Press the OK button to accept the new
setting.
• The control panel stops flashing and lights
up to display the torque clutch settings.
NOTE:
Check the new value after you change the
settings.
- 22 -
buttons as required to
Display
Seconds
30
3
1
0.1
0
OFF
as required to change
Display
Seconds
U9
3
U8
2.5
U7
2
U6
1.5
U5
1.2
U4
1
U3
0.7
U2
0.5
U1
0.3
U0
0.1
U
OFF