Panasonic EYFLA4A Operating Instructions Manual page 20

Cordless mechanical pulse driver
Hide thumbs Also See for EYFLA4A:
Table of Contents

Advertisement

Available languages

Available languages

Rundown error detecting function
EN
(EYFLA7, EYFLA8, EYFLA9,
EYFMA2)
The rundown error detecting function
causes a red indicator to flash if work
ends more quickly than a set time, for
example due to retightening of a previ-
ously tightened fastener or binding of the
screw's thread.
1. Set the tool to setting configuration
mode. (See page 18.)
2. Press the B button twice.
The rundown error detecting function set-
ting value will be displayed.
[Fig.28]
3. Press the
time as desired.
Buttons
4. Press the OK button to accept the
selected setting.
When the cross thread reduction function
is ON, the set time will be counted after
the tool operates in reverse for approxi-
mately 360°.
Radio signal range limitation
function on/off setting (EYFLA4AR,
EYFLA5AR, EYFLA5PR, EYFLA5QR,
EYFLA6JR, EYFLA6PR, EYFLA7AR,
EYFLA8AR, EYFLA8CR, EYFLA8PR,
EYFLA9CR, EYFLA9PR, EYFMA1JR,
EYFMA1PR, EYFMA2CR, EYFMA2PR)
1. Set the tool to configuration mode.
(See page 18.)
2. Press the C button.
The control panel will begin flashing.
Display: The letter "F" flashes on and off.
Battery indication lamp: The upper and lower
bars of the battery flash on and off.
[Fig.29]
and
buttons to change the
Display
Seconds
30
3
1
0.1
0
OFF
3. Press the C button again.
• Radio signal range limitation function
ON/OFF setting value will be displayed.
[Fig.30]
4. Press the
radio signal range limitation function
ON/OFF.
Radio signal
Display
range limitation
function mode
C0
OFF
C1
ON
5. Press the OK button to accept the
new setting.
Factory settings
• Radio signal range limitation function
setting: C0 (OFF)
NOTE:
• For more information about how to register
the tool and Assembly Qualifier, see the
Assembly Qualifier instruction manual.
Tightening time reminder
(EYFLA7, EYFLA8, EYFLA9,
EYFMA2)
The tool is locked when it reaches the set
tightening time, and the main unit stops
operation. This feature is convenient for
regular inspection of the tool performance.
1. Set the tool to setting configuration
mode. (See page 18.)
2. Press the C button twice.
The setting value will be displayed.
3. Press
and
change the time.
Operation
4. Press the OK button to accept the new
setting.
- 20 -
and
buttons to set
Status
Tool is operational in the ab-
sence of communications with
the Assembly Qualifier.
Tool is not operational
in the absence of com-
munications with the As-
sembly Qualifier.
buttons as required to
Display Tightening time
99
99 hours
1
1 hour
0
OFF

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents