Installation; Important.safety.notices - Pacific AK-9800 User & Installation Manual

Table of Contents

Advertisement

Available languages

Available languages

The installation instructions in this manual are intended for qualified installers who have
certification from local authorities to install mechanical and electrical devices, which in-
stallation conforms to local electrical and building codes.
The following safety notices must be read and fully understood before you begin instal-
lation of the range hood:
1. Use this unit only in the manner intended by the manufacturer. If you have questions
about the use of this product, please contact Pacific Range Hood Limited.
. Before installing, servicing, or cleaning the unit, switch the electrical power OFF at
the service panel and lock out the panel to prevent power from being accidentally
applied while you are working on, or around, the range hood.
3. Installation work must be done in accordance with local electrical and construction
codes. This includes Fire Rated construction.
. To prevent furnaces, fireplaces or other externally vented heating devices from ex-
periencing a reverse draft (back draft) through the flu or chimney, sufficient make-
up air is required for proper combustion and exhausting of gasses out of the house.
To negate this effect, local regulations may require that a damper be installed into
the ventilation duct work. The reader is cautioned to ensure that the installation of
your heating or ventilation equipment conforms to local codes.
5. When cutting into walls or ceilings, take care not to damage existing wiring or hid-
den utilities.
6. TO REDUCE THE RISK OF FIRE, ALWAYS USE METAL DUCT WORK! If old metal duct
work is to be reused, clean the duct work with a grease cutting solution to remove
accumulated grease and residue. Failure to do so may result in a fire. Check all sec-
tions and joints for proper connection and sealing. DO NOT use old duct work that is
less than 6" (153 mm) diameter.
7. NEVER use this range hood to exhaust explosive vapours such as gasoline, natural
gas, propane, or other similar substance - Explosions may result!
8. NEVER use this range hood to exhaust hazardous substances.
9. To avoid motor bearing damage and unbalanced fan impellers, keep drywall dust
and associated material off the fan unit.
10. It is recommended to mount the fan -3 inches (610-81 mm) from the cooking
surface.
11. Always exhaust external vents to the outside. Never vent into wall spaces, attics,
crawl spaces, or other enclosed areas.
1. Sharp edges are exposed around the duct opening and once the bottom grease
shield has been removed. To avoid injury, wearing protective gloves and appropriate
work clothing is recommended.

installation

IMPORTANT SAFETY NOTICES
Installation Safety Notices
Page 11