Si041138
8. Removal of Fan Motor
Procedure
Step
Release the fan motor
1
lead wires from the
hooks.
2
Loosen the screw of the
fan rotor.
Remove the 2 screws
3
of the fan motor fixing
plate.
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Removal of Fan Motor
Points
Preparation
Remove the drain pan unit
according to the "Removal of
Drain Pan Unit / Swing
Motor."
You can remove the fan
motor with the indoor heat
exchanger left.
(R4389)
(R15455)
Fan motor
fixing plate
(R4391)
23