Removal Of Electrical Box - Daikin FTE09MV2S Service Manual

Removal procedure. 9000/12000 btu/h class
Table of Contents

Advertisement

Si041138

5. Removal of Electrical Box

Procedure
Step
The figure shows the
1
connections of wire
harnesses.
Remove the screw of
2
the wire fixture.
3
Remove the 4 screws
of the terminal board
and disconnect the
connecting wires.
Disconnect the
4
connector for the swing
motor [S6].
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Drip proof
plate
Removal of Electrical Box
Preparation
Remove the front grille
according to the "Removal of
Electrical box
Front Grille."
(R12717)
Wire
fixture
(R12718)
Terminal
board
(R12719)
Put any excess wires behind
the power supply lead wire.
[S6]
(R12720)
Points
11