When the PVS switcher receives a valid SIS command, it executes the command
and sends a response to the host device. If the PVS is unable to execute the
command because the command is invalid or it contains invalid parameters, it
returns an error response to the host.
The error response codes and their descriptions are as follows:
E01 – Invalid input channel number (too large)
E06 – Invalid channel change
E10 – Invalid command
E13 – Invalid value (too large)
E14 – Invalid command for this configuration

Using the command/response tables

The command/response tables in this chapter list valid command ASCII codes, the
PVS's responses to the host, and a description of the command's function or the
results of executing the command. Upper and lower case characters may be used
interchangeably in the command field unless otherwise specified (setting gain/
attenuation, for example).
The ASCII to hexadecimal (HEX) conversion table below is for use with the
command/response tables.
ASCII to HEX Conversion Table
ASCII to Hex conversion table

Symbol definitions

]
= CR/LF (carriage return/line feed) (hex 0D 0A)
}
= CR (carriage return)
E
= Escape key
X!
= Specific input number (0 through 5 and 7)
0 = all output mute, both audio and video
1 and 2 = RGB inputs (also 1 and 2 in RGB/VGA group)
3 and 4 = RGB or composite video inputs
5 = Auxiliary audio only (not applicable with audio and video breakaway
commands). Not a switchable input.
7 = IR receiver microphone audio (not applicable with audio and video breakaway
commands). Not a switchable input.
8 = IR receiver auxiliary audio (not applicable with audio and video breakaway
commands). Not a switchable input.
X@
= Status
1 = Dual mono
2 = Stereo
PVS 305SA • Serial Communication