3.12.2. Outputting an External Synchronization Signal
A synchronization signal can be output externally on the FASTCAM MC1. The external
synchronization signal is output from the GENERAL OUT connector explained in section "3.10.
Input/Output Signal Types". The procedure for setting external synchronization signal output is
explained below.
1. Press the MENU key on the keypad and the menu list will display.
2. Select the GENERAL OUT from the SYNC IN/OUT submenu with the ARROW keys.
3. The menu is displayed. When performing external synchronization, use either SYNC POS
or SYNC NEG. View the chart on the next page for details.