Rsp_Ud: Data Transfer On Request; Short - Telegram (For Modules With Firmware 1.0.3 Or Older) - Honeywell FALCON MJ Pulse/M-Bus Operating Instructions Manual

M-bus module for honeywell / elster m100i and m120i waters meters
Table of Contents

Advertisement

4.2

RSP_UD: data transfer on request

Short - telegram (for Modules with Firmware 1.0.3 or older)

4.2.1
Field Name Content
Byte No
1
2
3
4
5
6
7
8 Ident.Nr.
9 Ident.Nr.
10 Ident.Nr.
11 Ident.Nr.
12 Manufr
13 Manufr
14 Version
17 Status
20
DR1
21
DR1
22
23
DR1
24
DR1
25
DR2
26
DR2
27
DR2
28
29
DR2
30
DR2
31
DR3
32
DR3
33
Falcon MJ M-Bus Operating instructions
OMS M-Bus frame
Length of data (xx bytes)
Length of data (xx bytes)
Respond user data
Secondary addressing mode
72h (long header)
Ident No LSB (BCD)
Ident No (BCD)
Ident No (BCD) (=12345678)
Ident No MSB (BCD)
Manufacturer code
Manufacturer code
Version (or Generation number)
Device type (Medium=Water)
Access number of Meter
M-Bus state
no Encryption
no Encryption
DIF (8 digit BCD)
VIF (Volume l)
Value LSB
Value ( = 28504,273 m³)
Value MSB
DIF (Time at readout; Type F)
VIF (Date, Time)
Value LSB
Value ( 31.05.2008 23:50 )
Value MSB
DIF (Date Stor. 1;Type G)
VIF (Date)
05/18 Generation 1.2
Water
meter
example
Bytes
[hex]
plain
68h
xxh
xxh
68h
08h
FDh
72h
78h
56h
34h
12h
92h
15h
xxh
07h
2Ah
00h
00h
00h
0Ch
13h
73h
42h
50h
28h
04h
6Dh
32h
37h
1Fh
15h
42h
6Ch
Page 17 of 38