Honeywell FALCON MJ Pulse/M-Bus Operating Instructions Manual page 18

M-bus module for honeywell / elster m100i and m120i waters meters
Table of Contents

Advertisement

DR3
Value
34
DR3
Value
35
DR4
DIF (8 digit BCD Stor. 1)
36
DR4
VIF (Volume l)
37
DR4
Value LSB
38
DR4
Value
39
DR4
Value ( = 12345,678 m³)
40
DR4
Value MSB
41
DR5
DIF (Date Stor. 1;Type G)
42
DR5
VIF (Date + Extension)
43
DR5
VIFE (Future Value)
44
DR5
Value
45
DR5
Value
46
DR6
DIF (8 digit BCD)
47
DR6
VIF (Volume l + Extension)
48
DR6
VIFE (backward flow)
49
DR6
Value LSB
50
DR6
Value
51
DR6
Value ( = 0,003 m³)
52
DR6
Value MSB
53
DR7
DIF (Date Max. Value; Type G)
54
DR7
VIF (Date)
55
DR7
Value
56
DR7
Value
57
DR8
DIF (16 bit Int, Max. Value)
58
DR8
VIF (Flow Rate l/h)
59
DR8
Value
60
DR8
Value
61
DR9
DIF (16 Bit Int)
62
DR9
VIF (Flow Rate l/h)
63
DR9
Value
64
DR9
Value
65
DR10
DIF (Backflow Alarm Date; Type F)
66
DR10
DIFE (Storage No. 7)
67
DR10
VIF (Date, Time)
68
DR10
Value LSB
69
DR10
Value
70
DR10
Value
71
DR10
Value MSB
72
DR11
DIF (Manipulation Alarm Date; Type F)
73
DR11
DIFE (Storage No. 6)
74
DR11
VIF (Date, Time)
75
DR11
Value LSB
76
DR11
Value
77
DR11
Value
78
DR11
Value MSB
79
Falcon MJ M-Bus Operating instructions
05/18 Generation 1.2
xxh
xxh
4Ch
13h
78h
56h
34h
12h
42h
ECh
7Eh
xxh
xxh
0Ch
93h
3Ch
03h
00h
00h
00h
12h
6Ch
xxh
xxh
12h
3Bh
xxh
xxh
02h
3Bh
xxh
xxh
C4h
03h
6Dh
xxh
xxh
xxh
xxh
84h
03h
6Dh
xxh
xxh
xxh
xxh
Page 18 of 38

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents