Advertisement

Quick Links

INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Please read carefully before proceeding with installation. Your failure to follow any attached
instructions or operating parameters may lead to the product's failure.
Refer to enclosed warranty and operating parameters to ensure proper use with your water supply.
Watts Premier
Phone: 800-752-5582
Manual: 199393
Save manual for future reference
MODEL
WP4V-50
System tested and certified by WQA against NSF/ ANSI Standard
53 & 58 for the reduction of the claims specified on the performance
data sheet and NSF/ ANSI Standard 372 for lead free.
8716 W Ludlow Drive, Suite 1
www.premierH2o.com
Warning
Page 1
Peoria, AZ 85381
Fax: 623-866-5666
Manual Date: 10/25/2016

Advertisement

Table of Contents
loading

Summary of Contents for Watts Premier WP4V-50

  • Page 1 53 & 58 for the reduction of the claims specified on the performance data sheet and NSF/ ANSI Standard 372 for lead free. Refer to enclosed warranty and operating parameters to ensure proper use with your water supply. Watts Premier 8716 W Ludlow Drive, Suite 1 Peoria, AZ 85381 Phone: 800-752-5582 www.premierH2o.com...
  • Page 2 RO water treatment system is equipped with a storage tank. Stage 4- VOC Block, recommend change 12 months. Premier WP4V-50 reverse osmosis system conforms to NSF/ANSI 58 for VOC reduction. Through the specialty formulated VOC post filter your system is capable of reducing harmful Volatile Organic Chemicals (VOC) like MTBE’s, Atrazine, Benzene, 2,4-D,Lindane and others from your drinking water.
  • Page 3: Table Of Contents

    Drill a Hole for the Reverse Osmosis Faucet .................. 6 How to use Quick Connect Fittings on Your RO System ..............6 Faucet Installation .......................... 7 Helpful Installation Tips for the Watts Top Mount Faucet ..............8 Adapt-a-Valve Installation ....................... 9 Drain Saddle Installation........................ 10 Drain Saddle Tube Connection......................
  • Page 4: Operational Parameters

    Operational Parameters Installation must comply with State and local plumbing regulations. Do not use with water that is micro biologically unsafe or of unknown quality without adequate disinfection before or after the system. System is intended to be installed using the cold water supply only. Maximum 100°F (37.8°C) Minimum 40°F (4.4°C) Operating Temperatures:...
  • Page 5: System Diagram And Parts List

    System Diagram and Parts List 3/8” BLACK TUBE 3/8” BLUE TUBE 1/4” TUBE 3/8” BLUE TUBE 1/4” GREEN TUBE Item Part # Description 101009 Carbon Block-10 Inch-5M COLD WATER 101013 VOC Carbon Block ANGLE-STOP 104017 Sediment Filter-10 Inch-5M (SUPPLY) 4 ALT 560016 RO Membrane 35GPD 560018...
  • Page 6: Drill A Hole For The Reverse Osmosis Faucet

    (If you are already using it for a sprayer or soap dispenser, see step 1) Porcelain sinks are extremely hard and can crack or chip easily. Use extreme caution when drilling. Watts accepts no responsibility for damage resulting from the installation of faucet. Diamond tip bit recommended.
  • Page 7: Faucet Installation

    Premier Monitored (Top Mount) Faucet Installation A) Connect tubes to the RO faucet (Figure A) This RO faucet is equipped with quick connect fittings for easy tube installation. To connect tubes, simply push them firmly into their corresponding fitting on the RO faucet until fully seated. Approximately 3/4”...
  • Page 8: Helpful Installation Tips For The Watts Top Mount Faucet

    Helpful Installation Tips for the Watts Top Mount Faucet During shipping/handling the tog- gle bolt on your new faucet may push up out of position. Prior to the install, hold the faucet as shown in the picture and pull down on the wing nut.
  • Page 9: Adapt-A-Valve Installation

    Adapt-a-Valve Installation Caution: Water supply line to the system must be from the cold water supply line only. Hot water will severely damage your system. Verify contents prior to installation: Black Collet ( 1 ) - Plastic Adapt-a-Valve with black collet ( 1 ) - Brass Adapter no washer ( 1 ) - Brass Adapter with black washer ( 1 ) - White rubber washer...
  • Page 10: Drain Saddle Installation

    Drain Saddle Installation Drain Saddle fits standard 1 ¼” – 1 ½” drain pipes Caution: If you have a garbage disposal, do not install the drain saddle near it. Installation of the drain saddle must be either above the garbage disposal, or if a second sink drain is available, install it above the cross bar on the second drain.
  • Page 11: Reverse Osmosis Module Mounting

    Reverse Osmosis Module Mounting Determine best location for the RO module to be mounted to allow Step 13 for future system maintenance. Using the mounting holes on the bracket, mark the location for the mounting screws on the cabinet wall under the sink. In the parts bag, locate the two self tapping screws.
  • Page 12: Start Up Instructions

    Congratulations! You have completed the installation of your new Reverse Osmosis system. Please Follow the Startup Instructions. Start up Instructions Turn on the incoming cold water at the angle stop valve and the Step 1 Adapt-a-Valve. Check the system for leaks and tighten any fittings as necessary.
  • Page 13: Maintenance & Troubleshooting

    MAINTENANCE & TROUBLESHOOTING 6 Month System Maintenance *Order filters by calling 1-800-752-5582 or buy online at www.premierH2o.com. √ Stage 1 - Sediment Filter (part #: 104017) √ Stage 2 - Carbon Block Filter (part #: 101009-White End Caps) Turn off the incoming water supply to the RO at the adapt-a-valve. Step 1 (Follow the green tube away from the RO system to find the adapt- a-valve.)
  • Page 14: Annual Maintenance

    Annual Maintenance *Order filters by calling 1-800-752-5582 or buy online at www.premierH2o.com Stage 1 - Sediment Filter (part #: 104017) • Stage 2 - Carbon Block Filter (part #: 101009 -White end caps) • Stage 4 - VOC Carbon Block Filter (part #: 101013 -Blue end caps) •...
  • Page 15: Membrane Replacement

    NOTICE: This is a good time to check the air pressure in your storage tank. For instructions please see page 16. Step 12: Follow Steps 8 through 10 in the Six Month System Maintenance (Page 13) for startup directions. This reverse osmosis system contains a replaceable component (the RO membrane) which is critical to the efficiency of the system.
  • Page 16: Check Air Pressure In The Tank

    Check Air Pressure in the Tank Important: Check air pressure only when tank is empty of water! Check air pressure in the storage tank when you notice a decrease in available water from the RO system. Air can be added with a bicycle pump using the schrader valve that is located on the lower side of the tank behind the blue plastic cap.
  • Page 17: Troubleshooting

    TROUBLE SHOOTING Problem Cause Solution 1. Low/Slow Production Low Water Pressure Assure a minimum of 40 psi incoming water pressure. Premier sells a booster pump if home water pressure is low. Maker sure water supply is turned on and Adapta Valve is all the way open Crimps in tubing Check tubing and straighten or replace as necessary.
  • Page 18: Performance Data Sheet

    TECHNICAL & WARRANTY INFORMATION Performance Data Sheet WP4V-50 Watts Premier 8716 W Ludlow Drive Sutie #1 Peoria, AZ 85381 85027 USA GENERAL USE CONDITIONS: 1. System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality. DO NOT use with water that is microbiologically unsafe or unknown quality without adequate disinfection before and after the system.
  • Page 19: Arsenic Fact Sheet

    Arsenic Fact Sheet Arsenic (As) is a naturally occurring contaminant found in many ground waters. Arsenic in water has no color, taste or odor. It must be measured by an arsenic test kit or lab test. Public water utilities must have their water tested for arsenic. You can obtain the results from your water utility contained with in your consumer confidence report.
  • Page 20: Voc Performance Data Sheet

    VOC Performance Data Sheet Watts Premier 8716 W Ludlow Drive Suite #1 Peoria, AZ 85381 USA Influent Challenge Maximum Substance Percent Reduction Concentration Permissible Product (mg/L unless noted) Water Concentration ALACHLOR >98% 0.05 0.001 ATRAZINE >97% 0.003 BENZENE >99% 0.081 0.001...
  • Page 21: Service Record

    Service Record Serial No. _____________________ Date of Purchase:__________ Date of Install:___________ Installed by:__________________ 3rd stage 2nd stage 4th stage 1st stage Date Membrane Carbon VOC Block Sediment (2-5 years) (6 months) (1 year) (6 months) NOTES: Page 21...
  • Page 22: Limited Warranty

    If any part of your Reverse Osmosis System is defective in workmanship (excluding replaceable filters and membranes), return unit after obtaining a return authorization (see below), less tank, within 1 year of original retail purchase, Watts Premier will repair or, at Watts Premier’s option, replace the system at no charge.

Table of Contents