Maico ECA 100 ipro Mounting And Operating Instructions page 19

Small room fan
Table of Contents

Advertisement

Available languages

Available languages

Night program
● Performance level 2 while room is being used,
performance level 1 during overrun time.
● J4 open, J5 open
100
90
80
70
60
50
40
30
20
10
0
Adjustable
Switch-controlled
start delay
operating time
Economy program
● Performance level 1 during operation and
overrun.
● J4 open, J5 bridged
100
90
80
70
60
50
40
30
20
10
0
Adjustable
Switch-controlled
start delay
operating time
Power program
● Performance level 2 during operation and
overrun.
● J4 bridged, J5 open
100
90
80
70
60
50
40
30
20
10
0
Adjustable
Switch-controlled
start delay
operating time
92 m³/h
78 m³/h
Adjustable
overrun time
92 m³/h
78 m³/h
Adjustable
overrun time
92 m³/h
78 m³/h
Adjustable
overrun time
 Fit electronics cover.
NOTICE
t
 Insert electronics cover into housing
recesses A, B and C with the 3 latches until
they snap into place. Press the electronics
cover firmly on to the housing at the points
indicated by the arrows.
t
 For unit versions F, KF, H, KH, B and KB,
insert the sensor supplied [9] in the correct
position (arrow X) in the connector base.
 Fit cover [6].
 Set start delay and overrun time in
accordance with Chapter 8.5.
 Fit designer cover [7] (see Fig. B).
t
Danger of short circuits and
damage to unit! Humidity will
penetrate if electronics cover
is not used correctly.
 Press electronics cover firmly
onto housing such that it is
sealed and flush all the way
around.
 Do not press setting buttons
[11] and [12].
GB
17