Appliance fails
to produce hot
water when set
on II/III heater
settings.
Any maintenance must be carried out by a qualified tradesperson, following the
instructions provided. Before replacing any parts, make sure that the underlying
cause of the malfunction has been resolved.
Warning! There are no user-serviceable components beneath the cover of the
appliance. Only a competent tradesperson should remove the cover.
Cleaning
Many household and industrial cleaners contain abrasive and chemical substances
that can damage the finish of your shower. Only clean the shower and fittings with
a mild washing-up detergent or soap solution, and then wipe them dry with a soft
cloth.
Handset - Cleaning
Clean with mild washing up detergent or soap solution. Wipe dry with a soft cloth.
Poor shower performance can be avoided by cleaning the spray plate. Use thumb
or soft cloth to wipe rubber nozzles. The handset must be descaled regularly.
Heater
Setting
I/II/III
ON
Any
Inlet valve, solenoid, or start/
stop switch faulty.
ON
Any
Supply pressure below 0.2
bar.
ON
II/III
Insufficient water supply.
ON
II/III
P o s s i b l e f a i l u r e o f t h e
microswitch or thermal switch.
ON
II/III
Heater Tank failure.

MAINTENANCE

Probable Cause
22
Possible Remedy
Replace as necessary.
Contact local water company.
Check mains water static
pressure.
Contact local water company.
Check the continuity of the
microswitch or heater tank and
replace parts as necessary.
Replace.