2. SPECIFICATIONS

2.1 Performance Data of Swimming Pool Heat Pump Unit

*** REFRIGERANT: R410A
Unit
Heating Capacity
Heating Power Input
Running Current
Power Supply
Compressor Quantity
Compressor(s)
Fan Quantity
Fan Power Input
Fan Rotate Speed
Fan Direction
Noise (at 1 meter)
Water Connection
Water Flow Volume Imperial/US m
Water Pressure Drop (max)
Unit Net Dimensions (L/W/H)
Unit Shipping Dimensions
(L/W/H)
Net Weight/Shipping Weight
Ambient temp (DB/WB): 80 ºF (26.7 º C) / 75.8 ºF ( 24.3 º C)
Heating:
Water temp (in/out): 80 ºF ( 26.7 º C) / 92 ºF ( 28 º C)
2
Model
HP50A1
kW
14.7
BTU/h
50,000
kW
2.68
A
12
V/Hz
208-230V~/60Hz 208-230V~/60Hz
1
Rotary
1
W
120
RPM
850
Horizontal
dB(A)
54
inch
1.5
/h/gpm
4.5/20
3
kPa/psi
10/1.5
1049x400x652 /
mm/in
41.3x15.7x25.7
1130x470x680 /
mm
44.5x18.5x26.8
kg
58/71
HP70A1
22.0
75,000
4.2
19
1
Rotary
1
120
850
Horizontal
56
1.5
6/26
12/1.5
1162x470x865 /
45.7x18.5x34
1220x490x880 /
48x19.3x34.6
106/123