6.1 To connect the common service tool

1. Connect the adapter cable for the common service
tool to the battery and the battery connector on the
product. Connect cable (A) to the common service
tool to do troubleshooting of the product. Connect
cable (B) to the common service tool to do
troubleshooting of the battery.

6.3 Troubleshooting of the product

Symptom
The product does not start. No LEDs
come on when you press the on/off
button.
Electrical motor makes sudden move-
ment when you push the power trig-
ger, then stops.
Product stops when you apply work
load.
Keypad lights flash.
Changing motor speed.
539 - 003 - 05.12.2018

6 Troubleshooting

A
B
Possible causes
Defective battery.
Defective plug between battery and
product.
Defective connection in keypad con-
nector.
Broken keypad.
Cables between control unit and key-
pad/main switch are damaged.
Short circuit in control unit.
Short circuit in control unit.
Defective connection in keypad con-
nector.
Defective connection in keypad con-
nector.
Short circuit in keypad.
Defective connection in main switch
signal connector.
Damaged or worn main switch.
Note: Refer to the manual for the common service
tool for instructions and obey the instructions.
2. Do troubleshooting as given in the common service
tool instructions.
6.2 To do troubleshooting of the common
service tool
If there is no signal to the common service tool when it is
connected to the product, do the procedure that follows.
1. Make sure that the connectors on the battery and on
the product are clean and not damaged. Replace the
battery or control unit on the product if there is
damage.
2. Make sure that the cable to the common service tool
is clean and not damaged. Replace the cable if there
is damage.
3. Restart the computer.
4. Install the software again.
Recommended step
Press the on/off button to do a check
of the battery. A minimum of 1 green
LED must come on.
Make sure that the power connectors
between the battery and the product
are not dirty or damaged.
Make sure that the keypad connector
is correctly assembled, dry, not dam-
aged and that there is no corrosion.
Replace keypad.
Repair/replace the cables if you can
see damages.
Replace control unit.
Replace the control unit.
Make sure that the power connectors
between battery and product are
clean and not damaged.
Make sure that the keypad connector
is correctly assembled, dry, not dam-
aged and that there is no corrosion.
Replace keypad.
Make sure that the keypad connector
is correctly assembled, dry, not dam-
aged and that there is no corrosion.
Replace keypad.