flashIng sequences anD transmIssIon behavIour
Problem
Battery voltage
too low
Valve drive slug-
gish
Actuating range
too wide
Adjustment
range too small
Device already
taught-in to
a MAX! Cube
or MAX! Wall
Thermostat +
Solution
Replace batteries
Check the installation; check
whether the pin on the heating
valve is stuck
Check the fastening of the radia-
tor thermostat
Check the heating valve; check
whether the valve pin is jammed
Make sure the device is no
longer taught-in to the MAX!
Cube (in the software) or the
MAX! Wall Thermostat + and
restore the factory settings Then
you can teach-in the device
again.