Problem
Filter pump won't start
or pump stops during
filtering.
Filter Pump runs, but
oil return is very slow.
Controller displays
OIL IN DRAIN
PAN / CONFIRM
6.2.4 Error Log Codes (For M3000 Controller Only)
Code
ERROR MESSAGE
E03
ERROR TEMP PROBE FAILURE
E04
HI 2 BAD
E05
HOT HI 1
E06
HEATING FAILURE
E20
INVALID CODE LOCATION
E21
CHANGE FILTER PAPER
E22
OIL IN PAN ERROR
E25
RECOVERY FAULT
E27
LOW TEMP ALARM
Probable Causes
A. Power cord is not plugged in or circuit
breaker is tripped.
B. Pump motor has overheated causing
the thermal overload switch to trip.
C. Blockage in filter pump.
Improperly installed or prepared filter pan
components or cold oil.
Drain valve open or possibility that oil is in
drain pan.
Corrective Action
A. Verify that the power cord is fully
plugged in and the circuit breaker is
not tripped.
B. If the motor is too hot to touch for
more than a few seconds, the
thermal
probably tripped. Allow the motor
to cool at least 45 minutes then press
the Pump Reset Switch. (See page 5-
4)
C. Call your FAS for assistance.
Remove the oil from the filter pan and
replace the filter paper, ensuring that
the filter screen is in place under the
paper.
Verify that O-rings are present and in
good condition on filter pan connection
fitting.
Press  (CONFIRM) and follow
directions for FILL VAT FROM
DRAIN PAN.
EXPLANATION
TEMP Probe reading out of range
High limit reading is out of range.
High limit temperature is past more than 410°F
(210°C), or in CE countries, 395°F (202°C)
A component has failed in the high limit circuit
such as controller, interface board, contactor or
open-high limit.
SD card removed during update
25 hour timer has expired. Change filter paper
and follow prompts.
Oil may be present in the filter pan.
Recovery time exceeded maximum time limit.
Recovery time should not exceed 1:40 for
electric.
Oil temperature has dropped 30°F (17°C) lower
than setpoint in idle mode or 45°F (25°C) in cook
mode. (This message may appear if a product is
dropped and the start cook button is not pressed
immediately or if too large of cook loads are
dropped.)
6-4