There is another category of SMS (for zero counter events)
– see the command summary.
These are subtly different, but quite important.
Type
SHO ZSMS.
#
InZ / OutZ
0:*
_ _ _ _ / _ _ _ _
1:*
_ _ _ _ / _ _ _ _
>
ONDELay and OFFDELay
To avoid false triggering on a noisy/chattering input, we can apply delays to the on and off input
states before they are acted upon by ControlMate.
Typing
SHO IN 3
will show detail about input #3. (
>sho in 3
[In
3] ON
ON
dly 3.0min
OFF dly 3.0min
IN ON
=[Daylight!]
IN OFF
=[Evening]
OnCmd =[OUT 0 on]
OffCmd=[OUT 0 off]
As well as showing the current state for input #3, this indicates there are DELAY values associated
with this input, along with the 'names' and command actions when the input changes state.
SMS ControlMate/3G © 2016-2018
SHO IN
displays all inputs, but in less detail)