4.5.4 Relation between remote operation and RUN/STOP status

This section explains the operations resulting from the combinations of the remote
operation and the RUN/STOP/MODE switch setting of the C Controller module.
(1) Relation between remote operation and RUN/STOP status of C
(2) Remote operations from the same development environment (personal
(3) Remote operation from multiple development environments (personal
(4) Remote operation from the C Controller module toward CPU No.1
4
- 51
4.5 Remote Operation Function
4.5.4 Relation between remote operation and RUN/STOP status
Controller module
The following table indicates the operations resulting from the combinations of the
remote operation and the RUN/STOP status of the C Controller module.
Table4.16 Relation between RUN/STOP status and remote operation
RUN/STOP/MODE switch
RUN
STOP
* 1 It is necessary to set "Remote reset" to "Allow" on the <<System setting>> tab of the C Controller
setting utility.
* 2 Resetting is executable when the C Controller module, whose RUN/STOP/MODE switch is set to
RUN, has been placed in the STOP status by remote STOP.
* 3 Including the case where the C Controller module is stopped due to an error.
computer) or user program
When more than one remote operation is attempted from the same development
environment (personal computer) or the same user program, the status caused by
later remote operation becomes effective.
computers) or user programs
Remote operation can be performed for the C Controller module where another
remote operation has already been executed from a different development
environment (personal computer) or user program.
(programmable controller CPU)
Remote operations are not executable from the C Controller module when remote
operation is executed to the CPU No.1 from the other peripheral devices (such as GX
Developer).
Execute remote RUN and cancel remote operation of the peripheral device where
remote operation is being performed.
For example, when remote PAUSE is executed in the other peripheral device, the
PAUSE status of the CPU No.1 will not change even if executing remote operation
from the C Controller module.
When executing remote RUN in the peripheral device where remote PAUSE is being
executed and canceling remote operation, remote operation from the C Controller
module can be executed.
Remote operation
RUN
STOP
RUN
STOP
STOP
STOP
*1
PAUSE
RESET
PAUSE
*2
*3
STOP
RESET