13
MULTIPLE CPU SYSTEM CONCEPT
(3) Outputs to output modules and intelligent function modules
(4) Access to intelligent function module buffer memory
ON/OFF data cannot be output to non-controlled modules.
When the outputs of the output modules and intelligent function modules controlled by
another CPU are turned ON/OFF from the C Controller module, they are not output to
the output modules and intelligent function modules.
/* Y is read in 1 word unit */
ret = QBF_Y_Out_WordEx(path, flg, yno, size, data, datasize);
Figure 13.21 When data are output from CPU No. 1 to modules
(a) Read from buffer memory
Using the bus interface function (QBF_FromBuf function), data can be read from
the buffer memory of the intelligent function module controlled by another CPU.
CPU
1
Figure 13.22 Read from intelligent function module
13.4 Access Ranges between CPU Modules and Other Modules
CPU
0
1
2
3
4
2
2
2
Can be turned ON/OFF
when bus interface function
is executed.
Cannot be turned ON/OFF.
0
1
2
3
4
5
2
1
1
1
1
2
Read when bus interface function
is executed.
13.4.2 Access to non-controlled modules
Slot number
Control CPU setting
Intelligent function modules
Slot number
6
7
2
2
Control CPU setting
13
9
10
11
12
13
14
15
16
- 20