MPS 601 • Setup Guide (Continued)
Connect Control Devices
NOTE:
Do not tin the leads. Tinned wires are not as secure in the connector and could be pulled out
Contact In/Tally Out —When a connected contact is grounded, the corresponding input is selected (see
previous page). At the same time, the tally output closes causing the Show Me cable LED indicator to light.
NOTE:
For "Show Me" cables, the ground pin is optional.
Do not connect "Show Me" cables to the +V pin of the +V Port (see below).
The six contacts are mutually exclusive so that only one input can be selected at a time.
Contact (C) – Momentary closure of this pin to ground selects the corresponding
number input. Selection is triggered at the closure (grounding) of the pin, not the
opening.
Ground (G) – Ground pin.
Tally output (C) – Controls the LEDs on the contact closure push button. When an input
is selected, the tally LED for that input is active.
+V Port — All three pins constantly output +5 VDC, 200 mA total (shared between pins).
The +V pins can provide power to illuminate external tally LEDs (
Remote RS-232 — Serial port for connection of a host computer or controller using
Simple Instruction Set (SIS™) or Windows-based control software commands (
The default protocol is 9600 baud, 8 data bits, 1 stop bit, and no parity.
An IP Link® driver allows Extron IPL and MediaLink® devices to control the MPS 601
from the RS-232 remote connector.

Connect Power

Connect the provided 12 VDC power supply to the rear panel captive
screw connector (
A
) and plug the AC power cord into 100-240 VAC,
at 50-60 Hz.
ATTENTION:
Always use a power supply provided by or specified by Extron. Use of an unauthorized power supply voids all
regulatory compliance certification and may cause damage to the supply and the end product.
Utilisez toujours une source d'alimentation fournie ou recommandée par Extron. L'utilisation d'une source
d'alimentation non autorisée annule toute conformité réglementaire et peut endommager la source d'alimentation ainsi
que le produit final.
Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling spaces or in wall cavities. The
power supply is to be located within the same vicinity as the Extron AV processing equipment in an ordinary location,
Pollution Degree 2, secured to the equipment rack within the dedicated closet, podium, or desk.
Sauf mention contraire, les adaptateurs AC/DC ne sont pas appropriés pour une utilisation dans les espaces d'aération
ou dans les cavités murales. La source d'alimentation doit être située à proximité de l'équipement de traitement
audiovisuel dans un endroit ordinaire, avec un degré 2 de pollution, fixé à un équipement de rack à l'intérieur d'un
placard, d'une estrade, ou d'un bureau.
2
G
).
H
).
Do not tin
the wires!
DC Power Cord
Captive Screw
Connector
3/16"
(5 mm) Max.
G
Ground
+12 VDC input
.
figure
1,
F
on the
C G
Do not tin
the wires!
Contact (NO)
Ground (G)
Tally (NO)
Do not tin
the wires!
+V
+V
+V
Tx
Rx
RS-232
Device
Bidirectional
Transmit (Tx)
Transmit (Tx)
Receive (Rx)
Receive (Rx)
_
_
Ground (
)
Ground (
)
Ground all
Devices
External Power Supply
(12 VDC, 0.5 A max.)
T